This file is indexed.

/var/lib/pcp/testsuite/282.out.pre-2.1 is in pcp-testsuite 3.8.12ubuntu1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
QA output created by 514

=======================
= chkconfig verbose on 
=======================

=== expect error: no $PCP_PMCDCONF_PATH ===
Waiting for pmcd to terminate ...
$PCP_RC_DIR/pmcd:
Warning: PMCD control file /etc/pmcd.conf is missing, cannot identify PMDAs
	 to be terminated.
$PCP_RC_DIR/pmcd:
Error: PMCD control file /etc/pmcd.conf is missing, cannot start PMCD.
=== probe pmcd: pmprobe: Cannot connect to PMCD on host "HOST": Connection refused

=== simple case, no frills, no errors ===
Starting pmcd ... 
Starting pmlogger ... 
=== probe pmcd: OK
=== probe pmlogger: OK

=== expected failure: a mere mortal ===
$PCP_RC_DIR/pmcd:
Error: You must be root (uid 0) to start or stop the Performance Co-Pilot PMCD.
=== probe pmcd: OK
=== start again ===
Waiting for pmcd to terminate ...
Starting pmcd ... 
Starting pmlogger ... 
=== probe pmcd: OK
=== probe pmlogger: OK

=== expect 2 x connect failure: pmcd is true(1), so hard for pmlogger ===
Waiting for pmcd to terminate ...
Starting pmcd ... 
$PCP_RC_DIR/pmcd:
Warning: Unable to contact PMCD, suggesting that PMCD may not have started.
         Check the file "$PCP_LOG_DIR/pcplog/pmcd.log" for possible
	 errors and/or warnings.
	 No attempt will be made to start the Performance Co-Pilot archive
         logger(s).
=== probe pmcd: pmprobe: Cannot connect to PMCD on host "HOST": Connection refused
=== probe pmlogger: Unable to connect to primary pmlogger at HOST: Connection refused
=== start again ===
Starting pmcd ... 
Starting pmlogger ... 
=== probe pmcd: OK
=== probe pmlogger: OK
=== expect difficulty terminating pmcd ... it has been sent a SIGSTOP ===
Waiting for pmcd to terminate .......
Process ...
-- ps output line --
$PCP_RC_DIR/pmcd: Warning: Forcing pmcd to terminate!
Starting pmcd ... 
=== probe pmcd: OK

=== expect warning: PMLOGGER.CHECK moved, so no pmlogger ===
Waiting for pmcd to terminate ...
Starting pmcd ... 
$PCP_RC_DIR/pmcd:
Warning: Performance Co-Pilot installation is incomplete (at least the
         script "/usr/pcp/bin/PMLOGGER.CHECK" is missing) and the PCP archive
         logger(s) cannot be started.
         You should install the pcp.sw.base ... PCP 2.0 or later ...
        ... consult PMLOGGER.CHECK(1), else
		# /sbin/chkconfig pmlogger off
=== probe pmcd: OK
=== probe pmlogger: Unable to connect to primary pmlogger at HOST: Connection refused

=== expect error: pmlogger/control moved, so no pmlogger ===
Waiting for pmcd to terminate ...
Starting pmcd ... 
Starting pmlogger ... 
$PCP_RC_DIR/pmcd:
Error: PCP archive logger control file $PCP_SYSCONF_DIR/pmlogger/control
       is missing!  Cannot start any Performance Co-Pilot archive logger(s).
=== probe pmcd: OK
=== probe pmlogger: Unable to connect to primary pmlogger at HOST: Connection refused

=== expect warning: host not in pmlogger/control, so initialize ===
Waiting for pmcd to terminate ...
Starting pmcd ... 
Starting pmlogger ... 
$PCP_RC_DIR/pmcd
Info: Initializing default PCP archive logger control for the primary
      logger in the file $PCP_SYSCONF_DIR/pmlogger/control - see
      PMLOGGER.CHECK(1) for details.
      This is a once only initialization after a PCP upgrade.
=== probe pmcd: OK
=== probe pmlogger: OK

=== expect pmlogger connect failure: same case, but pmlogger.options is bogus ===
Waiting for pmcd to terminate ...
Starting pmcd ... 
Starting pmlogger ... 
$PCP_RC_DIR/pmcd
Info: Initializing default PCP archive logger control for the primary
      logger in the file $PCP_SYSCONF_DIR/pmlogger/control - see
      PMLOGGER.CHECK(1) for details.
      This is a once only initialization after a PCP upgrade.
Restarting primary pmlogger for host "HOST" ... process exited!
PMLOGGER.CHECK: Error: failed to restart pmlogger
Current pmlogger processes:
... ps heading ...
Contents of pmlogger output file "pmlogger.log" ...
Log for pmlogger on HOST started DATE
pmlogger: Cannot open config file "/no/such/config": No such file or directory
Log finished DATE
PMLOGGER.CHECK: Error: archive file CHECK.0 missing
Directory ($PCP_LOG_DIR/pcplog/HOST) contents:
...
=== probe pmcd: OK
=== probe pmlogger: Unable to connect to primary pmlogger at HOST: Connection refused

=======================
= chkconfig verbose off 
=======================

=== expect error: no $PCP_PMCDCONF_PATH ===
$PCP_RC_DIR/pmcd:
Warning: PMCD control file "$PCP_PMCDCONF_PATH" is missing, cannot identify PMDAs
	 to be terminated.
$PCP_RC_DIR/pmcd:
Error: PMCD control file "$PCP_PMCDCONF_PATH" is missing, cannot start PMCD.
=== probe pmcd: pmprobe: Cannot connect to PMCD on host "HOST": Connection refused

=== simple case, no frills, no errors ===
=== probe pmcd: OK
=== probe pmlogger: OK

=== expected failure: a mere mortal ===
$PCP_RC_DIR/pmcd:
Error: You must be root (uid 0) to start or stop the Performance Co-Pilot PMCD.
=== probe pmcd: OK
=== start again ===
=== probe pmcd: OK
=== probe pmlogger: OK

=== expect 2 x connect failure: pmcd is true(1), so hard for pmlogger ===
$PCP_RC_DIR/pmcd:
Warning: Unable to contact PMCD, suggesting that PMCD may not have started.
         Check the file "$PCP_LOG_DIR/pmcd.log" for possible
	 errors and/or warnings.
	 No attempt will be made to start the Performance Co-Pilot archive
         logger(s).
=== probe pmcd: pmprobe: Cannot connect to PMCD on host "HOST": Connection refused
=== probe pmlogger: Unable to connect to primary pmlogger at HOST: Connection refused
=== start again ===
=== probe pmcd: OK
=== probe pmlogger: OK
=== expect difficulty terminating pmcd ... it has been sent a SIGSTOP ===
Process ...
-- ps output line --
$PCP_RC_DIR/pmcd: Warning: Forcing pmcd to terminate!
=== probe pmcd: OK

=== expect warning: PMLOGGER.CHECK moved, so no pmlogger ===
$PCP_RC_DIR/pmcd:
Warning: Performance Co-Pilot installation is incomplete (at least the
         script "/usr/pcp/bin/PMLOGGER.CHECK" is missing) and the PCP archive
         logger(s) cannot be started.
         You should install the pcp.sw.base ... PCP 2.0 or later ...
        ... consult PMLOGGER.CHECK(1), else
		# /sbin/chkconfig pmlogger off
=== probe pmcd: OK
=== probe pmlogger: Unable to connect to primary pmlogger at HOST: Connection refused

=== expect error: pmlogger/control moved, so no pmlogger ===
$PCP_RC_DIR/pmcd:
Error: PCP archive logger control file $PCP_SYSCONF_DIR/pmlogger/control
       is missing!  Cannot start any Performance Co-Pilot archive logger(s).
=== probe pmcd: OK
=== probe pmlogger: Unable to connect to primary pmlogger at HOST: Connection refused

=== expect warning: host not in pmlogger/control, so initialize ===
$PCP_RC_DIR/pmcd
Info: Initializing default PCP archive logger control for the primary
      logger in the file $PCP_SYSCONF_DIR/pmlogger/control - see
      PMLOGGER.CHECK(1) for details.
      This is a once only initialization after a PCP upgrade.
=== probe pmcd: OK
=== probe pmlogger: OK

=== expect pmlogger connect failure: same case, but pmlogger.options is bogus ===
$PCP_RC_DIR/pmcd
Info: Initializing default PCP archive logger control for the primary
      logger in the file $PCP_SYSCONF_DIR/pmlogger/control - see
      PMLOGGER.CHECK(1) for details.
      This is a once only initialization after a PCP upgrade.
Restarting primary pmlogger for host "HOST" ... process exited!
PMLOGGER.CHECK: Error: failed to restart pmlogger
Current pmlogger processes:
... ps heading ...
Contents of pmlogger output file "pmlogger.log" ...
Log for pmlogger on HOST started DATE
pmlogger: Cannot open config file "/no/such/config": No such file or directory
Log finished DATE
PMLOGGER.CHECK: Error: archive file CHECK.0 missing
Directory ($PCP_LOG_DIR/pcplog/HOST) contents:
...
=== probe pmcd: OK
=== probe pmlogger: Unable to connect to primary pmlogger at HOST: Connection refused

Restore the state of the universe ...
Waiting for pmcd to terminate ...
Starting pmcd ... 
Starting pmlogger ...