This file is indexed.

/usr/share/doc/argyll/ccxxmake.html is in argyll 1.5.1-5ubuntu1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
  <head>
    <title>ccxxmake</title>
    <meta http-equiv="content-type" content="text/html;
      charset=ISO-8859-1">
    <meta name="author" content="Graeme Gill">
  </head>
  <body>
    <h2><b>spectro/ccxxmake</b></h2>
    <h3>Summary</h3>
    For Colorimeters that rely on a calibration matrix, <span
      style="font-weight: bold;">ccxxmake</span> allows creation of a
    correction matrix file (<a href="File_Formats.html#.ccmx">ccmx</a>)
    for a particular <span style="font-weight: bold;">Colorimeter &amp;
      Display</span> combination, by making use a reference <span
      style="font-weight: bold;">Spectrometer</span> or Colorimeter
    instrument. This can then be used to improve the accuracy of
    subsequent measurements with that Colorimeter on that Display by
    using it with the <a href="dispcal.html#X">dispcal</a>, <a
      href="dispread.html#X">dispread</a> and <a href="spotread.html#X">spotread</a>
    -X option. A ccmx file can also be <a href="oeminst.html">installed</a>,
    and will then appear in the available display type selection (<b>-y</b>
    option). See <a href="WideGamutColmters.html">Wide Gamut Displays
      and Colorimeters</a> for more information on why this may be
    useful. [ <span style="font-weight: bold;">Note</span> that to make
    use of a <u>colorimeter</u> as a CCMX reference, you will have to
    provide two .ti3 files rather than using interactive measurement-
    see <a href="#f"><span style="font-weight: bold;">-f</span></a>. ]<br>
    <br>
    For Colorimeters that have sensor spectral sensitivity calibration
    information built into them&nbsp; (ie. the X-Rite <span
      style="font-weight: bold;">i1d3</span>, and<span
      style="font-weight: bold;"><span style="font-weight: bold;"></span></span>
    DataColor <span style="font-weight: bold;">Spyder4</span>), <span
      style="font-weight: bold;">ccxxmake</span> allows a creation of a
    calibration spectral sample (<a href="File_Formats.html#.ccss">ccss</a>)
    for a particular <span style="font-weight: bold;">Display</span>,
    by making use a reference <span style="font-weight: bold;">Spectrometer</span>
    instrument. This can then be used to improve the accuracy of
    subsequent measurements on that Display using such Colorimeters, by
    using it with the <a href="dispcal.html#X">dispcal</a>, <a
      href="dispread.html#X">dispread</a> and <a href="spotread.html#X">spotread</a>
    -X option, or it can be <a
      href="file:///D:/src/argyll/doc/oeminst.html">installed</a>, and
    will then appear in the available display type selection (<b>-y</b>
    option).<br>
    <br>
    The instrument manufacturer may supply spectral sample files (see <a
      href="oeminst.html">oeminst</a>).<br>
    <br>
    There is a <a href="ccmxs.html">list of contributed</a> <span
      style="font-weight: bold;">ccmx</span> (Colorimeter Correction
    Matrix) files.<br>
    <h3>Usage Summary</h3>
    <small style="font-family: monospace;">ccxxmake [-options]
      correction.ccmx<br>
    </small><small style="font-family: monospace;">&nbsp;<a href="#v">-v</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;













      &nbsp; &nbsp; &nbsp; Verbose mode</small><br>
    &nbsp; <a href="#S">-S</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Create
CCSS
rather













    than CCMX<br>
    &nbsp; <a href="#f">-f file1.ti3[,file2.ti3]</a>
    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Create
from
one
or
two













    .ti3 files rather than measure.<br style="font-family: monospace;">
    <span style="font-family: monospace;">&nbsp;</span><font
      style="font-family: monospace;" size="-1"><a href="#display">-display













        displayname</a>&nbsp; [X11 only] Choose X11 display name</font><br
      style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1"></font><font
      style="font-family: monospace;" size="-1">&nbsp;<a href="#dnm">-d
        n[,m]</a>
      &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
      [X11 only] Choose the display from the following list (default 1),</font><br
      style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
and
optionally
choose
a
different
display
m













      for VideoLUT access.</font><br style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;<a href="#d">-d













        n</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Choose
the
display
from
the
following
list













      (default 1)</font><br>
    <span style="font-family: monospace;">&nbsp;<a href="#dweb">-dweb[:port]</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;

















      Display via a web server at port (default 8080)</span><br
      style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;</font><font
      style="font-family: monospace;" size="-1"><a href="#p">-p</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;













      Use telephoto mode (ie. for a projector) (if available)</font><br
      style="font-family: monospace;">
    &nbsp; <font size="-1"><span style="font-family: monospace;"><a
          href="#y">-y X</a>
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;













        Display type - instrument specific list to choose from.</span></font><font
      style="font-family: monospace;" size="-1"> (CCMX)</font><br
      style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;<a href="#P">-P













        ho,vo,ss[,vs]</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Position test
      window and scale it</font><br style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
ho,vi:
0.0
=
left/top,
0.5
=
center,













      1.0 = right/bottom etc.</font><br style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
ss:
0.5
=
half,
1.0
=
normal,













      2.0 = double etc.</font><br>
    <font size="-1"><span style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;







        ss,vs: = optional horizontal, vertical scale.</span></font><br
      style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;</font><font
      style="font-family: monospace;" size="-1"><a href="#F">-F</a>
      &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;













      Fill whole screen with black background</font><br
      style="font-family: monospace;">
    <small style="font-family: monospace;">&nbsp;<span
        style="text-decoration: underline;"></span><a href="#n">-n</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
[X11
only]
Don't
set
override
redirect
on













      test window<br>
    </small><font style="font-family: monospace;" size="-1">&nbsp;<a
        href="#N">-N</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;













      Disable initial calibration of instrument</font><small
      style="font-family: monospace;"> if possible<br>
    </small><span style="font-family: monospace;">&nbsp;</span><font
      style="font-family: monospace;" size="-1"><a href="#H">-H</a>
      &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;













      Use high resolution spectrum mode (if available)</font><font
      style="font-family: monospace;" size="-1"></font><br
      style="font-family: monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;<a href="#C">-C













        "command"</a> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
      Invoke shell "command" each time a color is set<br>
    </font><small style="font-family: monospace;">&nbsp;<a href="#o">-o
        <i>observ</i></a>&nbsp; &nbsp; &nbsp; &nbsp;
      &nbsp;&nbsp;&nbsp;&nbsp; Choose CIE Observer for CCMX spectral
      data:<br>
      &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
      &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;&nbsp;&nbsp; 1931_2 </small><small
      style="font-family: monospace;"> (def.)</small><small
      style="font-family: monospace;">, 1964_10, S&amp;B 1955_2, shaw,
      J&amp;V 1978_2<br>
    </small><font style="font-family: monospace;" size="-1">&nbsp;<a
        href="#s">-s steps</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Override
default
patch
sequence













      combination steps (default 3)</font><br style="font-family:
      monospace;">
    <font style="font-family: monospace;" size="-1">&nbsp;<a href="#W">-W













        n|h|x</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Override
serial
port
flow
control:
n
=













      none, h = HW, x = Xon/Xoff</font><br style="font-family:
      monospace;">
    <small style="font-family: monospace;">&nbsp;<a href="#D">-D [level]</a>
      &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Print
      debug diagnostics to stderr<br>
    </small><small style="font-family: monospace;">&nbsp;<a
        href="ccxxmake.html#E">-E "description"</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Override
the
default
overall













      escription</small><br>
    <small style="font-family: monospace;">&nbsp;<a href="#I">-I
        "displayname"</a> &nbsp;&nbsp;&nbsp;&nbsp; </small><span
      style="font-family: monospace;">Set display make and model
      description</span><small style="font-family: monospace;"><br>
      &nbsp;</small><small style="font-family: monospace;"><a href="#T">-T













        "displaytech"</a> &nbsp;&nbsp;&nbsp;&nbsp; </small><span
      style="font-family: monospace;">Set display technology description</span>
    (ie. CRT, LCD etc.)<small style="font-family: monospace;"></small><br>
    <tt>&nbsp;<a href="#U">-U c</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;

      Set UI selection character(s)</tt><br>
    <font size="-1"><span style="font-family: monospace;">&nbsp;</span><a
        style=" font-family: monospace;" href="#Yrn">-<font size="-1">Y</font>
        r|n</a><span style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;









        &nbsp;&nbsp;&nbsp;&nbsp; Override refresh, non-refresh display
        mode</span></font><br>
    <font size="-1"><span style="font-family: monospace;">&nbsp;</span><a
        style=" font-family: monospace;" href="#YA">-<font size="-1">Y</font>A</a><span
        style="font-family: monospace;">
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp;&nbsp;&nbsp;&nbsp; Use non-adaptive integration time mode
        (if available).</span></font><br style="font-family: monospace;">
    <span style="font-family: monospace;">&nbsp;</span><font
      style="font-family: monospace;" size="-1"><a href="#file1"><span
          style="font-style: italic;">correction.ccmx</span></a> |&nbsp;<a
        href="#file2"></a></font><font style="font-family: monospace;"
      size="-1"><a href="ccxxmake.html#file2">calibration.ccss</a></font><font
      style="font-family: monospace;" size="-1"><br>
      &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;
      &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; File to save result to.</font><br>
    <h3>Usage Details and Discussion</h3>
    <a name="v"></a>The <b>-v</b> flag causes extra information to be
    printed out during chartread operation.<br>
    <br>
    <a name="S"></a><span style="font-weight: bold;">-S</span> By
    default a Colorimeter Correction Matrix (<span style="font-weight:
      bold;">CCMX</span>) will be created from both <span
      style="font-weight: bold;">Colorimeter</span> and <span
      style="font-weight: bold;">Spectrometer</span> readings, which
    allows correction for errors with a particular Colorimeter and
    Display combination. If the <span style="font-weight: bold;">-S</span>
    flag is used, then instead a Colorimeter Calibration Spectral Set (<span
      style="font-weight: bold;">CCSS</span>) file is created from just
    the <span style="font-weight: bold;">Spectrometer</span> readings,
    that allows calibrating any suitable Colorimeter to the Display.<br>
    <br>
    <a name="f"></a><span style="font-weight: bold;">-f <span
        style="font-style: italic;">file1.ti3[,file2.ti3]</span></span>
    By <span style="text-decoration: underline;">default</span> <span
      style="font-weight: bold;">ccxxmake</span> creates a <span
      style="font-weight: bold;">CCMX</span> file by displaying test
    patches on the screen, and then prompting you to measure them
    interactively with the two instruments. An alternative is to create
    a small number of test values using <span style="font-weight:
      bold;">targen</span> suitable for display profiling (or use the <span
      style="font-weight: bold;">ref/ccxx.ti1</span> file provided with
    ArgyllCMS), and then measure them with the two instruments using <span
      style="font-weight: bold;">dispread</span> to create a reference
    and target .ti3 files, and then provide the two files as arguments
    to <span style="font-weight: bold;">ccxxmake -f</span>. Normally
    the reference file will be created using a spectral instrument and
    you will want to use the <span style="font-weight: bold;">-s</span>
    flag with dispread for this. If you want to use a colorimeter as a
    reference instrument, then make sure that it is the first file
    provided to the ccxxmake <span style="font-weight: bold;">-f</span>
    option. The filenames should be concatenated with a <span
      style="font-weight: bold;">","</span> separator without spaces.
    You will also have to supply a display name using the <span
      style="font-weight: bold;">-I</span> option and/or technology
    description using <span style="font-weight: bold;">-T</span>.<br>
    When creating a <span style="font-weight: bold;">CCSS</span> file,
    only spectral readings from the display measured with the reference
    instrument are needed, and a single <span style="font-weight:
      bold;">.ti3</span> file should be provided.<br>
    <br>
    <a name="display"></a>When running on a UNIX based system that used
    the X11 Windowing System, <b>ccxxmake</b> will by default use the
    $DISPLAY environment variable to determine which display and screen
    to read from. This can be overridden by supplying an X11 display
    name to the <span style="font-weight: bold;">-display</span>
    option. Note that if Xinerama is active, you can't select the screen
    using $DISPLAY or -display, you have to select it using the <span
      style="font-weight: bold;">-d</span> parameter.<br>
    <br>
    <a name="d"></a> By default the main display will be the location of
    the test window. If the system has more than one display or screen,
    an alternate display/screen can be selected with the <span
      style="font-weight: bold;">-d</span> parameter. If you invoke <b>ccxxmake</b>
    so as to display the usage information (i.e. "dispcal -?" or
    "dispcal --"), then the discovered displays/screens will be listed.
    Multiple displays may not be listed, if they appear as a single
    display to the operating system (ie. the multi-display support is
    hidden in the video card driver). On UNIX based system that used the
    X11 Windowing System, the <span style="font-weight: bold;">-d</span>
    parameter will override the screen specified by the $DISPLAY or
    parameter.<br>
    <br>
    <a name="dnm"></a>Because of the difficulty cause by TwinView and
    MergedFB in X11 based systems, you can optionally specify a separate
    display number after the display that is going to be used to present
    test patches, for accessing the VideoLUT hardware. This must be
    specified as a single string, e.g. <span style="font-weight: bold;">-d













      1,2</span> . Some experimentation may be needed using <a
      href="dispwin.html">dispwin</a> on such systems, to discover what
    screen has access to the VideoLUT hardware, and which screens the
    test patches appear on.<br>
    <br>
    <span style="font-weight: bold;"><a name="dweb"></a>-dweb</span> or
    <span style="font-weight: bold;">-dweb:port</span> starts a
    standalone web server on your machine, which then allows a local or
    remote web browser to display the the color test patches. By default
    port <span style="font-weight: bold;">8080</span> is used, but this
    can be overridden by appending a <span style="font-weight: bold;">:</span>
    and the port number i.e. <span style="font-weight: bold;">-dweb:8001</span>.
    The URL will be <span style="font-weight: bold;">http://</span>
    then name of the machine or its I.P. address followed by a colon and
    the port number - e.g something like <span style="font-weight:
      bold;">http://192.168.0.1:8080</span>. If you use the verbose
    option (<span style="font-weight: bold;">-v</span>) then a likely
    URL will be printed once the server is started, or you could run <span
      style="font-weight: bold;">ipconfig</span> (MSWin) or <span
      style="font-weight: bold;">/sbin/ifconfig</span> (Linux or OS X)
    and identify an internet address for your machine that way.<br>
    <br>
    <a name="p"></a>The <span style="font-weight: bold;">-p</span> flag
    allows measuring in telephoto mode, using instruments that support
    this mode, e.g. the ColorMunki. Telephoto mode is one for taking
    emissive measurements from a distance (ie. telespectometer,
    tele-colorimeter) mode, and typically would be used for measuring
    projector type displays. If a device does not support a specific
    telephoto mode, then the normal emissive mode may be suitable for
    measuring projectors.<br>
    <br>
    <a name="y"></a> The <span style="font-weight: bold;">-y</span>
    flag allows setting the Display Type used as a base for color
    correction matrix CCMX creation. Only base calibration display types
    will be listed. The selection typically determines two aspects of of
    the instrument operation: <span style="font-weight: bold;">1)</span>
    It may set the measuring mode to suite <a
      href="http://en.wikipedia.org/wiki/Comparison_of_display_technology"><span
        style="font-weight: bold;">refresh</span> or <span
        style="font-weight: bold;">non-refresh</span> displays</a>.
    Typically only LCD (Liquid Crystal) displays have a non-refresh
    nature. <span style="font-weight: bold;">2)</span> It may select an
    instrument internal calibration matrix suitable for a particular
    display type. The selections available depends on the type and model
    of instrument, and a list of the options for the discovered
    instruments will be shown in the <a href="ArgyllDoc.html#CmdLine">usage</a>
    information. For more details on what particular instruments support
    and how this works, see <a href="instruments.html">Operation of
      particular instruments</a>. Any CCMX created will work on top of
    the selected Display Type, so to be valid, the same Display Type
    must be selected whenever the CCMX is used with this instrument.
    Installed CCMX files will automatically select the appropriate base
    type.<br>
    <br>
    <a name="P"></a> The <span style="font-weight: bold;">-P</span>
    parameter allows you to position and size the test patch window. By
    default it is places in the center of the screen, and sized
    appropriately for the type of instrument. The <span
      style="font-weight: bold;">ho</span> and <span
      style="font-weight: bold;">vo</span> values govern the horizontal
    and vertical offset respectively. A value of 0.0 positions the
    window to the far left or top of the screen, a value of 0.5
    positions it in the center of the screen (the default), and 1.0
    positions it to the far right or bottom of the screen. If three
    parameters are provided, then the <span style="font-weight: bold;">ss</span>
    parameter is a scale factor for the test window size. A value of 0.5
    for instance, would produce a half sized window. A value of 2.0 will
    produce a double size window. If four parameters are provided, then
    the last two set independent horizontal and vertical scaling
    factors. Note that the ho,vo,ss or ho,vo,hs,vs numbers must be
    specified as a single string (no space between the numbers and the
    comma). For example, to create a double sized test window at the top
    right of the screen, use <span style="font-weight: bold;">-P 1,0,2</span>
    . To create a window twice as wide as high: <span
      style="font-weight: bold;">-P 1,0,2,1</span>.<br>
    <br>
    <a name="F"></a> The <span style="font-weight: bold;">-F</span>
    flag causes the while screen behind the test window to be masked
    with black. This can aid black accuracy when measuring CRT displays
    or projectors.<br>
    <br>
    <a name="n"></a><span style="font-weight: bold;">-n</span> When
    running on a UNIX based system that used the X11 Windowing System, <b>dispcal</b>
    normally selects the override redirect so that the test window will
    appear above any other windows on the display. On some systems this
    can interfere with window manager operation, and the <b>-n</b>
    option turns this behaviour off.<br>
    <br>
    <a name="N"></a><span style="font-weight: bold;">-N</span> Any
    instrument that requires regular calibration will ask for
    calibration on initial start-up. Sometimes this can be awkward if
    the instrument is being mounted in some sort of measuring jig, or
    annoying if several sets of readings are being taken in quick
    succession. The -<span style="font-weight: bold;">N</span>
    suppresses this initial calibration if a valid and not timed out
    previous calibration is recorded in the instrument or on the host
    computer. It is advisable to only use this option on the second and
    subsequent measurements in a single session.<br>
    <br>
    <a name="L"></a> The -<span style="font-weight: bold;">H</span>
    option on high resolution spectral mode, if the instrument supports
    it, such as the Eye-One Pro. See <a href="instruments.html">Operation












      of particular instruments</a> for more details. This may give
    better accuracy for display measurements.<br>
    <br>
    <a name="C"></a> The -<span style="font-weight: bold;">C</span> <span
      style="font-weight: bold;">"command" </span>option allows a
    method of relaying each test value to some other display than that
    on the system running dispcal (for instance, a photo frame, PDA
    screen etc.), by causing the given command to be invoked to the
    shell, with six arguments. The first three arguments are the RGB
    test color as integers in the range 0 to 255, the second three
    parameters are the RGB test color as floating point numbers in the
    range 0.0 to 1.0. The script or tool should relay the given color to
    the screen in some manner (e.g. by generating a raster file of the
    given color and sending it to the display being profiled), before
    returning. Note that a test window will also be created on the
    system running dispread.<br>
    <br>
    <a name="o"></a> (CCMX creation) The <b>-o</b> flag allows
    specifying a tristimulus observer, and is used to compute
    tristimulus values from spectral readings.&nbsp; The following
    choices are available:<br>
    <b>&nbsp; 1931_2</b> selects the standard CIE 1931 2 degree
    observer. The default.<br>
    &nbsp; <b>1964_10</b> selects the standard CIE 1964 10 degree
    observer.<br>
    &nbsp; <b>1955_2</b> selects the Stiles and Birch 1955 2 degree
    observer<br>
    &nbsp; <b>1978_2 </b>selects the Judd and Voss 1978 2 degree
    observer<br>
    &nbsp; <b>shaw</b> selects the Shaw and Fairchild 1997 2 degree
    observer<br>
    <br>
    <a name="s"></a>The <b>-s steps</b><span style="font-weight: bold;"></span>
    parameter overrides the default number of test patch combination
    steps used in measuring a colorimeter &amp; display combination.<span
      style="font-weight: bold;"></span><span style="font-weight: bold;"></span><span
      style="font-weight: bold;"></span>&nbsp; The steps are those out
    of every combination of R,G &amp; B values of the given number of
    steps that have at least one colorant at 100%. So 2 steps gives 7
    test patches, 3 gives 19, 4 gives 37, 5 gives 61, 6 gives 91 etc.
    Note that typically this won't make much difference to the resulting
    calibration, since it depends primarily on the underlying spectral
    characteristics of the display.<br>
    <br>
    <a name="W"></a>The <b>-W</b> <span style="font-weight: bold;">n|h|x</span>
    parameter overrides the default serial communications flow control
    setting. The value <span style="font-weight: bold;">n</span> turns
    all flow control off, <span style="font-weight: bold;">h</span>
    sets hardware handshaking, and <span style="font-weight: bold;">x</span>
    sets Xon/Xoff handshaking. This commend may be useful in workaround
    serial communications issues with some systems and cables. <br>
    <br>
    <a name="D"></a>The <b>-D</b> flag causes communications and other
    instrument diagnostics to be printed to stdout. A level can be set
    between 1 .. 9, that may give progressively more verbose
    information, depending on the instrument. This can be useful in
    tracking down why an instrument can't connect.<br>
    <br>
    <a name="E"></a>The <b>-E</b> parameter allows overriding the <span
      style="font-weight: bold;">ccmx/ccss</span> files overall
    description tag. Normally this is not necessary. With most command
    line shells, it will be necessary to enclose the parameter with
    double quotes, so that spaces and other special characters are
    included in the parameter, and not mistaken for the start of another
    flag, or as a final command line parameter. <br>
    <br>
    <a name="I"></a>The <b>-I</b> parameter allows setting of the
    display description string in the resulting <span
      style="font-weight: bold;">ccmx/ccss</span> file. Since the
    default display description is probably very generic, it is <span
      style="font-weight: bold;">highly recommended</span> that a
    description of the make and model of the display be provided here,
    or set a display technology description using <span
      style="font-weight: bold;">-T</span> (see below). The default or
    given display description will be printed before the menu. With most
    command line shells, it will be necessary to enclose the parameter
    with double quotes, so that spaces and other special characters are
    included in the parameter, and not mistaken for the start of another
    flag, or as a final command line parameters.<br>
    <br>
    <a name="T"></a>The <b>-T</b> parameter allows setting of the
    display technology description string in the resulting <span
      style="font-weight: bold;">ccmx/ccss</span> file. The
    applicability of the calibration mainly depends on the technology
    type of the display, so a description of the technology (ie. "CRT",
    "LCD", "LCD + backlight type + LCD type",&nbsp; etc.) is <span
      style="font-weight: bold;">highly recommended</span>, because it
    can make the calibration more widely usable. With most command line
    shells, it will be necessary to enclose the parameter with double
    quotes, so that spaces and other special characters are included in
    the parameter, and not mistaken for the start of another flag, or as
    a final command line parameters.<br>
    <br>
    <a name="U"></a>The <b>-U</b> parameter allows setting of the user
    interface selection character this display type can be selected by,
    if installed. This character will only be used if there is no clash
    with any preceding selections. Characters in the range 0-9, A-Z a-z
    can be used.<br>
    <br>
    <a name="Yrn"></a>The -<span style="font-weight: bold;">Y r </span>and








    <b>-Y n</b> options overrides the refresh display mode set by the <a
      href="file:///D:/src/argyll/doc/spotread.html#y">-y display type
      selection</a>, with <b>-Y</b><span style="font-weight: bold;"> r</span>
    forcing refresh display mode, and <b>-Y n</b> forcing a non-refresh
    display mode. Not all instruments support a display measurement
    refresh mode, or the ability to override the mode set by the display
    type selection.<br>
    <br>
    <a name="YA"></a> The -<span style="font-weight: bold;">Y A</span>
    option uses a non-adaptive integration time emission measurement
    mode, if the instrument supports it, such as the Eye-One Pro or
    ColorMunki. By default an adaptive integration time measurement mode
    will be used for emission measurements, but some instruments support
    a fixed integration time mode that can be used with display devices.
    This may give increased consistency and faster measurement times,
    but may also give less accurate low level readings.<br>
    <br>
    <a name="file1"></a>The <span style="font-weight: bold; font-style:
      italic;">correction.ccmx</span> is the name of the file to save
    the resulting <a href="File_Formats.html#.ccmx">Colorimeter
      Correction Matrix</a> to. It is best to give it a short but
    informative name that includes the Colorimeter model and the display
    make and model. By convention it should have a <span
      style="font-weight: bold;">.ccmx</span> file extension.<br>
    <br>
    <a name="file2"></a>The <span style="font-weight: bold; font-style:
      italic;">correction.ccss</span> is the name of the file to save
    the resulting <a href="File_Formats.html#.ccss">Colorimeter
      Calibration Spectral Samples</a> to. It is best to give it a short
    but informative name that includes the display technology or model.
    By convention it should have a <span style="font-weight: bold;">.ccss</span>
    file extension.<br>
    <br>
    If you are going to use the same CCMX or CCSS file all the time,
    then you may want to set the <a href="Environment.html">ARGYLL_COLMTER_CAL_SPEC_SET</a>
    environment variable.<br>
    <br>
    <hr style="width: 100%; height: 2px;">
    <h3>Instrument Communications:</h3>
    Unlike the other measurement utilities,<span style="font-weight:
      bold;"> ccxxmake</span> doesn't connect to the instrument until it
    is about to make a measurement. This allows for the possibility of
    using a different instrument for each measurement.<br>
    <br>
    It will display a menu:<span style="font-style: italic;"></span><br>
    <br>
    Press 1 .. 4:<br>
    1) Select an instrument, Currently 1 'usb:/bus4/dev2/ (GretagMacbeth
    i1 Pro)'<br>
    2) Measure test patches with current instrument<br>
    3) [ Compute Colorimeter Correction Matrix &amp; save it ]<br>
    4) Exit<br>
    <br>
    For creating a CCMX there are two measurements to be made, after
    which the correction matrix can be computed and saved. Before each
    measurement, the instrument may need calibrating. For creating a
    CCSS a single measurement is needed.<br>
    <br>
    &nbsp;A spectral measurement using a spectral instrument is always
    needed.<br>
    <br>
    &nbsp;A measurement using the Colorimeter that the correction matrix
    is being created for is needed in the case of creating a CCMX, but <span
      style="font-weight: bold;">not</span> needed when creating a CCSS.<br>
    <br>
    There will be a message before the menu indicating which of the
    measurements has been completed.<br>
    <br>
    <hr style="width: 100%; height: 2px;">
    <h4>Display Setup:</h4>
    Because ccmx/ccss is measuring spectral matching, the exact levels
    of each channel is not important, so the display settings or
    calibration state shouldn't make any difference to the result, as
    long as it is the same for the readings of both instruments.
    Similarly, the number and variety of test patches shouldn't make a
    huge difference, as long as there is at least Red, Green, Blue and
    White test patches.<br>
    &nbsp;<br>
    <br>
    <br>
    <br>
    <br>
    <br>
    <br>
    <br>
    <br>
    <br>
    <br>
    <br>
    <br>
  </body>
</html>