This file is indexed.

/usr/share/pyshared/pymodbus/constants.py is in python-pymodbus 1.2.0-2.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
'''
Constants For Modbus Server/Client
----------------------------------

This is the single location for storing default
values for the servers and clients.
'''
from pymodbus.interfaces import Singleton


class Defaults(Singleton):
    ''' A collection of modbus default values

    .. attribute:: Port

       The default modbus tcp server port (502)

    .. attribute:: Retries

       The default number of times a client should retry the given
       request before failing (3)

    .. attribute:: Timeout

       The default amount of time a client should wait for a request
       to be processed (3 seconds)

    .. attribute:: Reconnects

       The default number of times a client should attempt to reconnect
       before deciding the server is down (0)

    .. attribute:: TransactionId

       The starting transaction identifier number (0)

    .. attribute:: ProtocolId

       The modbus protocol id.  Currently this is set to 0 in all
       but proprietary implementations.

    .. attribute:: UnitId

       The modbus slave addrss.  Currently this is set to 0x00 which
       means this request should be broadcast to all the slave devices
       (really means that all the devices should respons).

    .. attribute:: Baudrate

       The speed at which the data is transmitted over the serial line.
       This defaults to 19200.

    .. attribute:: Parity

       The type of checksum to use to verify data integrity. This can be
       on of the following::

         - (E)ven - 1 0 1 0 | P(0)
         - (O)dd  - 1 0 1 0 | P(1)
         - (N)one - 1 0 1 0 | no parity

       This defaults to (N)one.

    .. attribute:: Bytesize

       The number of bits in a byte of serial data.  This can be one of
       5, 6, 7, or 8. This defaults to 8.

    .. attribute:: Stopbits

       The number of bits sent after each character in a message to
       indicate the end of the byte.  This defaults to 1.
    '''
    Port          = 502
    Retries       = 3
    Timeout       = 3
    Reconnects    = 0
    TransactionId = 0
    ProtocolId    = 0
    UnitId        = 0x00
    Baudrate      = 19200
    Parity        = 'N'
    Bytesize      = 8
    Stopbits      = 1


class ModbusStatus(Singleton):
    '''
    These represent various status codes in the modbus
    protocol.

    .. attribute:: Waiting

       This indicates that a modbus device is currently
       waiting for a given request to finish some running task.

    .. attribute:: Ready

       This indicates that a modbus device is currently
       free to perform the next request task.

    .. attribute:: On

       This indicates that the given modbus entity is on

    .. attribute:: Off

       This indicates that the given modbus entity is off

    .. attribute:: SlaveOn

       This indicates that the given modbus slave is running

    .. attribute:: SlaveOff

       This indicates that the given modbus slave is not running
    '''
    Waiting  = 0xffff
    Ready    = 0x0000
    On       = 0xff00
    Off      = 0x0000
    SlaveOn  = 0xff
    SlaveOff = 0x00


class Endian(Singleton):
    ''' An enumeration representing the various byte endianess.

    .. attribute:: Auto

       This indicates that the byte order is chosen by the
       current native environment.

    .. attribute:: Big

       This indicates that the bytes are in little endian format

    .. attribute:: Little

       This indicates that the bytes are in big endian format

    .. note:: I am simply borrowing the format strings from the
       python struct module for my convenience.
    '''
    Auto   = '@'
    Big    = '>'
    Little = '<'


class ModbusPlusOperation(Singleton):
    ''' Represents the type of modbus plus request

    .. attribute:: GetStatistics

       Operation requesting that the current modbus plus statistics
       be returned in the response.

    .. attribute:: ClearStatistics

       Operation requesting that the current modbus plus statistics
       be cleared and not returned in the response.
    '''
    GetStatistics   = 0x0003
    ClearStatistics = 0x0004


class DeviceInformation(Singleton):
    ''' Represents what type of device information to read

    .. attribute:: Basic

       This is the basic (required) device information to be returned.
       This includes VendorName, ProductCode, and MajorMinorRevision
       code.

    .. attribute:: Regular

       In addition to basic data objects, the device provides additional
       and optinoal identification and description data objects. All of
       the objects of this category are defined in the standard but their
       implementation is optional.

    .. attribute:: Extended

       In addition to regular data objects, the device provides additional
       and optional identification and description private data about the
       physical device itself. All of these data are device dependent.

    .. attribute:: Specific

       Request to return a single data object.
    '''
    Basic    = 0x01
    Regular  = 0x02
    Extended = 0x03
    Specific = 0x04


class MoreData(Singleton):
    ''' Represents the more follows condition

    .. attribute:: Nothing

       This indiates that no more objects are going to be returned.

    .. attribute:: KeepReading

       This indicates that there are more objects to be returned.
    '''
    Nothing     = 0x00
    KeepReading = 0xFF

#---------------------------------------------------------------------------#
# Exported Identifiers
#---------------------------------------------------------------------------#
__all__ = [
    "Defaults", "ModbusStatus", "Endian",
    "ModbusPlusOperation",
    "DeviceInformation", "MoreData",
]