/etc/sane.d/umax.conf is in libsane 1.0.23-3ubuntu3.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 | #
# Options for the umax backend
#
# define scsi queueing depth
#option scsi-maxqueue 2
# define scsi buffer size in bytes
#option scsi-buffer-size-min 65536
#option scsi-buffer-size-max 262144
# define scan lines that shall be read in one block
#option scan-lines 100
#option preview-lines 20
# define how to handle bad sense codes
# 0 = handle as device busy
# 1 = handle as ok
# 2 = handle as i/o error
# 3 = ignore bad error code - continue sense handler,
#option handle-bad-sense-error 0
# define if a request sense command shall be executed
#option execute-request-sense 0
# define if the preview bit shall be set when scanning in rgb mode
#option force-preview-bit-rgb 0
# define if slow speed flag shall be set
# BE CAREFUL WITH THIS OPTION, IT MAY DESTROY YOUR SCANNER WHEN SET FALSE
# -1 = automatically set by driver - if known
# 0 = disabled
# 1 = enabled
#option slow-speed 0
# define if care-about-smeraring flag shall be set
# BE CAREFUL WITH THIS OPTION, IT MAY DESTROY YOUR SCANNER WHEN SET FALSE
# -1 = automatically set by driver - if known
# 0 = disabled
# 1 = enabled
#option care-about-smearing 0
# define if the calibration shall be done for selected scanarea or for each ccd pixel
# -1 = automatically set by driver - if known
# 0 = disabled
# 1 = enabled
#option calibration-full-ccd 1
# define if an offset of the calculate calibration with has to be used
# -99999 = auto
#option calibration-width-offset -99999
# define the number of pixels that is used for calibration
# -1 = disabled
# 0 = not set
# 1 = 1 byte/pixel,
# 2 = 2 bytes/pixel
#option calibration-bytes-pixel -1
# define if scanner uses the same exposure times for red, green and blue
# -1 = automatically set by driver - if known
# 0 = disabled (own selection for red, green and blue)
# 1 = enabled (same values for red, green and blue)
#options exposure-time-rgb-bind 0
# define if shading data shall be inverted befor sending it back to the scanner
# -1 = automatically set by driver - if known
# 0 = disabled
# 1 = enabled
#option invert-shading-data 0
# define if the scanner supports lamp control commands
# 0 = automatically set by driver - if known
# 1 = enabled
#option lamp-control-available 0
# define how 16 bit gamma data is padded
# -1 = automatically set by driver - if known
# 0 = gamma data is msb padded
# 1 = gamma data is lsb padded
#option gamma-lsb-padded 0
# define connection type of following devices
# 1 = scsi
# 2 = usb
#option connection-type 1
# linux device identification:
#scsi vendor model type bus channel id lun
scsi UMAX * Scanner
scsi LinoHell JADE
scsi LinoHell Office
scsi LinoHell Office2
scsi LinoHell SAPHIR2
scsi LinoHell SAPHIR3
scsi Linotype SAPHIR4
scsi LinoHell OPAL2
scsi HDM LS4H1S
scsi Nikon AX-110
scsi Nikon AX-210
scsi KYE ColorPage-HR5
scsi EPSON Perfection600
scsi ESCORT "Galleria 600S"
scsi TriGem PowerScanII
# Umax Astra 2200 via USB:
# usb vendor product
usb 0x1606 0x0230
# scsi device list
option connection-type 1
/dev/scanner
# usb device list
option connection-type 2
/dev/usbscanner
|