This file is indexed.

/usr/share/ElmerGUI/edf-extra/k-epsilon.xml is in elmer-common 6.1.0.svn.5396.dfsg-2ubuntu1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
<?xml version='1.0' encoding='UTF-8'?>
<!DOCTYPE edf>
<edf version="1.0" >
   <PDE Name="K-Epsilon" >
      <Name>K-Epsilon</Name>

      <Equation>
         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Equation-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Equation-block of the SIF as such. </StatusTip>
	 </Parameter>
      </Equation>

      <Solver>
         <Parameter Widget="Edit" >
            <Name > Procedure </Name>
            <DefaultValue> "KESolver" "KESolver" </DefaultValue>
         </Parameter>

         <Parameter Widget="Label"> <Name>Additional Variables</Name> </Parameter>
         <Parameter Widget="Edit">
           <Name> Exported Variable 1 </Name>
           <Activate> /K-Epsilon/Solver/Exported Variable 2</Activate>
         </Parameter>
         <Parameter Widget="Edit" Enabled="False" Visible="False">
           <Name> Exported Variable 2 </Name>
           <Activate> /K-Epsilon/Solver/Exported Variable 3</Activate>
         </Parameter>
         <Parameter Widget="Edit" Enabled="False" Visible="False">
           <Name> Exported Variable 3 </Name>
           <Activate> /K-Epsilon/Solver/Exported Variable 4</Activate>
         </Parameter>
         <Parameter Widget="Edit" Enabled="False" Visible="False">
           <Name> Exported Variable 4 </Name>
           <Activate> /K-Epsilon/Solver/Exported Variable 5</Activate>
         </Parameter>
         <Parameter Widget="Edit" Enabled="False" Visible="False">
           <Name> Exported Variable 5 </Name>
         </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Solver-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Solver-block of the SIF as such. </StatusTip>
	 </Parameter>

      </Solver>

      <BodyForce>
         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Body Force-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Body Force-block of the SIF as such. </StatusTip>
	 </Parameter>
      </BodyForce>

      <Material>
         <Parameter Widget="Label" > <Name> Properties </Name> </Parameter>
         <Parameter Widget="Edit" >
            <Name> KE Clip </Name>
         </Parameter>

         <Parameter Widget="Edit" >
            <Name> KE Cmu </Name>
         </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Material-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Material-block of the SIF as such. </StatusTip>
	 </Parameter>
      </Material>

      <InitialCondition>
         <Parameter Widget="Label" > <Name> Variables </Name> </Parameter>
         <Parameter  Widget="Edit">
           <Name> Kinetic Energy </Name>
         </Parameter>
         <Parameter  Widget="Edit">
           <Name> Kinetic Dissipation </Name>
         </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Initial Condition-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Initial Condition-block of the SIF as such. </StatusTip>
	 </Parameter>
      </InitialCondition>

      <BoundaryCondition>
         <Parameter Widget="Label" > <Name> Dirichlet Conditions </Name> </Parameter>
         <Parameter  Widget="Edit">
           <Name> Kinetic Energy </Name>
           <Activate> /K-Epsilon/BoundaryCondition/Kinetic Energy Condition </Activate>
         </Parameter>

         <Parameter  Widget="Edit">
           <Name> Kinetic Dissipation Rate</Name>
           <SifName> Kinetic Dissipation </SifName>
           <Activate> /K-Epsilon/BoundaryCondition/Kinetic Dissipation Condition </Activate>
         </Parameter>

         <Parameter  Widget="Edit">
           <Name> Kinetic Dissipation Rate Boundary Relaxation </Name>
           <SifName> Epsilon Relax </SifName>
         </Parameter>

         <Parameter  Widget="Edit" Enabled="False">
           <Name> Kinetic Energy Condition </Name>
           <Whatis> If the given value is less than zero, apply flux condition insted of the Dirichlet Condition. To be generally useful space and/or time varying values may be given. </Whatis>
           <StatusTip> Give kinetic energy condition value for this boundary. </StatusTip>
         </Parameter>

         <Parameter  Widget="Edit" Enabled="False">
           <Name> Kinetic Dissipation Condition </Name>
           <Whatis> If the given value is less than zero, apply flux condition insted of the Dirichlet Condition. To be generally useful space and/or time varying values may be given. </Whatis>
           <StatusTip> Give kinetic energy dissipation condition value for this boundary. </StatusTip>
         </Parameter>

         <Parameter Widget="Label" > <Name> Wall law </Name> </Parameter>

         <Parameter  Widget="CheckBox">
           <Name> Reichardts Wall Law </Name>
           <SifName> Wall Law </SifName>
           <Activate> /K-Epsilon/BoundaryCondition/Boundary Layer Thickness </Activate>
         </Parameter>

         <Parameter  Widget="Edit" Enabled="False">
           <Name> Boundary Layer Thickness </Name>
         </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Boundary Condition-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Boundary Condition-block of the SIF as such. </StatusTip>
	 </Parameter>
      </BoundaryCondition>
   </PDE>
</edf>