/usr/share/doc/libvirt-doc/formatdomain.html is in libvirt-doc 0.9.8-2ubuntu17.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050 3051 3052 3053 3054 3055 3056 | <?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
<html xmlns="http://www.w3.org/1999/xhtml">
<!--
This file is autogenerated from formatdomain.html.in
Do not edit this file. Changes will be lost.
-->
<head>
<meta http-equiv="Content-Type" content="text/html; charset=UTF-8" />
<link rel="stylesheet" type="text/css" href="main.css" />
<link rel="SHORTCUT ICON" href="32favicon.png" />
<title>libvirt: Domain XML format</title>
<meta name="description" content="libvirt, virtualization, virtualization API" />
</head>
<body>
<div id="header">
<div id="headerLogo"></div>
<div id="headerSearch">
<form action="search.php" enctype="application/x-www-form-urlencoded" method="get"><div>
<input id="query" name="query" type="text" size="12" value="" />
<input id="submit" name="submit" type="submit" value="Search" />
</div></form>
</div>
</div>
<div id="body">
<div id="menu">
<ul class="l0"><li>
<div>
<a title="Front page of the libvirt website" class="inactive" href="index.html">Home</a>
</div>
</li><li>
<div>
<a title="Details of new features and bugs fixed in each release" class="inactive" href="news.html">News</a>
</div>
</li><li>
<div>
<a title="Applications known to use libvirt" class="inactive" href="apps.html">Applications</a>
</div>
</li><li>
<div>
<a title="Get the latest source releases, binary builds and get access to the source repository" class="inactive" href="downloads.html">Downloads</a>
</div>
</li><li>
<div>
<a title="Information for users, administrators and developers" class="active" href="docs.html">Documentation</a>
<ul class="l1"><li>
<div>
<a title="How to compile libvirt" class="inactive" href="compiling.html">Compiling</a>
</div>
</li><li>
<div>
<a title="Information about deploying and using libvirt" class="inactive" href="deployment.html">Deployment</a>
</div>
</li><li>
<div>
<a title="Overview of the logical subsystems in the libvirt API" class="inactive" href="intro.html">Architecture</a>
</div>
</li><li>
<div>
<a title="Description of the XML formats used in libvirt" class="active" href="format.html">XML format</a>
<ul class="l2"><li>
<div>
<span class="active">Domains</span>
</div>
</li><li>
<div>
<a title="The virtual network XML format" class="inactive" href="formatnetwork.html">Networks</a>
</div>
</li><li>
<div>
<a title="Network filter XML format" class="inactive" href="formatnwfilter.html">Network Filtering</a>
</div>
</li><li>
<div>
<a title="The storage pool and volume XML format" class="inactive" href="formatstorage.html">Storage</a>
</div>
</li><li>
<div>
<a title="Storage volume encryption XML format" class="inactive" href="formatstorageencryption.html">Storage Encryption</a>
</div>
</li><li>
<div>
<a title="The driver capabilities XML format" class="inactive" href="formatcaps.html">Capabilities</a>
</div>
</li><li>
<div>
<a title="The host device XML format" class="inactive" href="formatnode.html">Node Devices</a>
</div>
</li><li>
<div>
<a title="The secret XML format" class="inactive" href="formatsecret.html">Secrets</a>
</div>
</li><li>
<div>
<a title="The snapshot XML format" class="inactive" href="formatsnapshot.html">Snapshots</a>
</div>
</li></ul>
</div>
</li><li>
<div>
<a title="Hypervisor specific driver information" class="inactive" href="drivers.html">Drivers</a>
</div>
</li><li>
<div>
<a title="Reference manual for the C public API" class="inactive" href="html/index.html">API reference</a>
</div>
</li><li>
<div>
<a title="Bindings of the libvirt API for other languages" class="inactive" href="bindings.html">Language bindings</a>
</div>
</li><li>
<div>
<a title="Working on the internals of libvirt API, driver and daemon code" class="inactive" href="internals.html">Internals</a>
</div>
</li><li>
<div>
<a title="A guide and reference for developing with libvirt" class="inactive" href="devguide.html">Development Guide</a>
</div>
</li><li>
<div>
<a title="Command reference for virsh" class="inactive" href="virshcmdref.html">Virsh Commands</a>
</div>
</li></ul>
</div>
</li><li>
<div>
<a title="User contributed content" class="inactive" href="http://wiki.libvirt.org">Wiki</a>
</div>
</li><li>
<div>
<a title="Frequently asked questions" class="inactive" href="http://wiki.libvirt.org/page/FAQ">FAQ</a>
</div>
</li><li>
<div>
<a title="How and where to report bugs and request features" class="inactive" href="bugs.html">Bug reports</a>
</div>
</li><li>
<div>
<a title="How to contact the developers via email and IRC" class="inactive" href="contact.html">Contact</a>
</div>
</li><li>
<div>
<a title="Available test suites for libvirt" class="inactive" href="testsuites.html">Test suites</a>
</div>
</li><li>
<div>
<a title="Miscellaneous links of interest related to libvirt" class="inactive" href="relatedlinks.html">Related Links</a>
</div>
</li><li>
<div>
<a title="Overview of all content on the website" class="inactive" href="sitemap.html">Sitemap</a>
</div>
</li></ul>
</div>
<div id="content">
<h1>Domain XML format</h1>
<ul><li>
<a href="#elements">Element and attribute overview</a>
<ul><li>
<a href="#elementsMetadata">General metadata</a>
</li><li>
<a href="#elementsOS">Operating system booting</a>
<ul><li>
<a href="#elementsOSBIOS">BIOS bootloader</a>
</li><li>
<a href="#elementsOSBootloader">Host bootloader</a>
</li><li>
<a href="#elementsOSKernel">Direct kernel boot</a>
</li></ul>
</li><li>
<a href="#elementsSysinfo">SMBIOS System Information</a>
</li><li>
<a href="#elementsCPUAllocation">CPU Allocation</a>
</li><li>
<a href="#elementsCPUTuning">CPU Tuning</a>
</li><li>
<a href="#elementsMemoryAllocation">Memory Allocation</a>
</li><li>
<a href="#elementsMemoryBacking">Memory Backing</a>
</li><li>
<a href="#elementsMemoryTuning">Memory Tuning</a>
</li><li>
<a href="#elementsNUMATuning">NUMA Node Tuning</a>
</li><li>
<a href="#elementsBlockTuning">Block I/O Tuning</a>
</li><li>
<a href="#elementsCPU">CPU model and topology</a>
</li><li>
<a href="#elementsLifecycle">Lifecycle control</a>
</li><li>
<a href="#elementsFeatures">Hypervisor features</a>
</li><li>
<a href="#elementsTime">Time keeping</a>
</li><li>
<a href="#elementsDevices">Devices</a>
<ul><li>
<a href="#elementsDisks">Hard drives, floppy disks, CDROMs</a>
</li><li>
<a href="#elementsFilesystems">Filesystems</a>
</li><li>
<a href="#elementsControllers">Controllers</a>
</li><li>
<a href="#elementsLease">Device leases</a>
</li><li>
<a href="#elementsUSB">USB and PCI devices</a>
</li><li>
<a href="#elementsRedir">Redirected devices</a>
</li><li>
<a href="#elementsSmartcard">Smartcard devices</a>
</li><li>
<a href="#elementsNICS">Network interfaces</a>
<ul><li>
<a href="#elementsNICSVirtual">Virtual network</a>
</li><li>
<a href="#elementsNICSBridge">Bridge to LAN</a>
</li><li>
<a href="#elementsNICSSlirp">Userspace SLIRP stack</a>
</li><li>
<a href="#elementsNICSEthernet">Generic ethernet connection</a>
</li><li>
<a href="#elementsNICSDirect">Direct attachment to physical interface</a>
</li><li>
<a href="#elementsNICSMulticast">Multicast tunnel</a>
</li><li>
<a href="#elementsNICSTCP">TCP tunnel</a>
</li><li>
<a href="#elementsNICSModel">Setting the NIC model</a>
</li><li>
<a href="#elementsDriverBackendOptions">Setting NIC driver-specific options</a>
</li><li>
<a href="#elementsNICSTargetOverride">Overriding the target element</a>
</li><li>
<a href="#elementsNICSBoot">Specifying boot order</a>
</li><li>
<a href="#elementQoS">Quality of service</a>
</li><li>
<a href="#elementLink">Modyfing virtual link state</a>
</li></ul>
</li><li>
<a href="#elementsInput">Input devices</a>
</li><li>
<a href="#elementsHub">Hub devices</a>
</li><li>
<a href="#elementsGraphics">Graphical framebuffers</a>
</li><li>
<a href="#elementsVideo">Video devices</a>
</li><li>
<a href="#elementsConsole">Consoles, serial, parallel & channel devices</a>
<ul><li>
<a href="#elementsCharGuestInterface">Guest interface</a>
<ul><li>
<a href="#elementCharParallel">Parallel port</a>
</li><li>
<a href="#elementCharSerial">Serial port</a>
</li><li>
<a href="#elementCharConsole">Console</a>
</li><li>
<a href="#elementCharChannel">Channel</a>
</li></ul>
</li><li>
<a href="#elementsCharHostInterface">Host interface</a>
<ul><li>
<a href="#elementsCharSTDIO">Domain logfile</a>
</li><li>
<a href="#elementsCharFle">Device logfile</a>
</li><li>
<a href="#elementsCharVC">Virtual console</a>
</li><li>
<a href="#elementsCharNull">Null device</a>
</li><li>
<a href="#elementsCharPTY">Pseudo TTY</a>
</li><li>
<a href="#elementsCharHost">Host device proxy</a>
</li><li>
<a href="#elementsCharPipe">Named pipe</a>
</li><li>
<a href="#elementsCharTCP">TCP client/server</a>
</li><li>
<a href="#elementsCharUDP">UDP network console</a>
</li><li>
<a href="#elementsCharUNIX">UNIX domain socket client/server</a>
</li></ul>
</li></ul>
</li><li>
<a href="#elementsSound">Sound devices</a>
</li><li>
<a href="#elementsWatchdog">Watchdog device</a>
</li><li>
<a href="#elementsMemBalloon">Memory balloon device</a>
</li></ul>
</li><li>
<a href="#seclabel">Security label</a>
</li></ul>
</li><li>
<a href="#examples">Example configs</a>
</li></ul>
<p>
This section describes the XML format used to represent domains, there are
variations on the format based on the kind of domains run and the options
used to launch them. For hypervisor specific details consult the
<a href="drivers.html">driver docs</a>
</p>
<h2>
<a name="elements" id="elements">Element and attribute overview</a>
</h2>
<p>
The root element required for all virtual machines is
named <code>domain</code>. It has two attributes, the
<code>type</code> specifies the hypervisor used for running
the domain. The allowed values are driver specific, but
include "xen", "kvm", "qemu", "lxc" and "kqemu". The
second attribute is <code>id</code> which is a unique
integer identifier for the running guest machine. Inactive
machines have no id value.
</p>
<h3>
<a name="elementsMetadata" id="elementsMetadata">General metadata</a>
</h3>
<pre>
<domain type='xen' id='3'>
<name>fv0</name>
<uuid>4dea22b31d52d8f32516782e98ab3fa0</uuid>
<description>Some human readable description</description>
...</pre>
<dl><dt><code>name</code></dt><dd>The content of the <code>name</code> element provides
a short name for the virtual machine. This name should
consist only of alpha-numeric characters and is required
to be unique within the scope of a single host. It is
often used to form the filename for storing the persistent
configuration file. <span class="since">Since 0.0.1</span></dd><dt><code>uuid</code></dt><dd>The content of the <code>uuid</code> element provides
a globally unique identifier for the virtual machine.
The format must be RFC 4122 compliant,
eg <code>3e3fce45-4f53-4fa7-bb32-11f34168b82b</code>.
If omitted when defining/creating a new machine, a random
UUID is generated. It is also possible to provide the UUID
via a <a href="#elementsSysinfo"><code>sysinfo</code></a>
specification. <span class="since">Since 0.0.1, sysinfo
since 0.8.7</span></dd><dt><code>description</code></dt><dd>The content of the <code>description</code> element provides a
human readable description of the virtual machine. This data is not
used by libvirt in any way, it can contain any information the user
wants. <span class="since">Since 0.7.2</span></dd></dl>
<h3>
<a name="elementsOS" id="elementsOS">Operating system booting</a>
</h3>
<p>
There are a number of different ways to boot virtual machines
each with their own pros and cons.
</p>
<h4>
<a name="elementsOSBIOS" id="elementsOSBIOS">BIOS bootloader</a>
</h4>
<p>
Booting via the BIOS is available for hypervisors supporting
full virtualization. In this case the BIOS has a boot order
priority (floppy, harddisk, cdrom, network) determining where
to obtain/find the boot image.
</p>
<pre>
...
<os>
<type>hvm</type>
<loader>/usr/lib/xen/boot/hvmloader</loader>
<boot dev='hd'/>
<boot dev='cdrom'/>
<bootmenu enable='yes'/>
<smbios mode='sysinfo'/>
<bios useserial='yes'/>
</os>
...</pre>
<dl><dt><code>type</code></dt><dd>The content of the <code>type</code> element specifies the
type of operating system to be booted in the virtual machine.
<code>hvm</code> indicates that the OS is one designed to run
on bare metal, so requires full virtualization. <code>linux</code>
(badly named!) refers to an OS that supports the Xen 3 hypervisor
guest ABI. There are also two optional attributes, <code>arch</code>
specifying the CPU architecture to virtualization,
and <code>machine</code> referring to the machine
type. The <a href="formatcaps.html">Capabilities XML</a>
provides details on allowed values for
these. <span class="since">Since 0.0.1</span></dd><dt><code>loader</code></dt><dd>The optional <code>loader</code> tag refers to a firmware blob
used to assist the domain creation process. At this time, it is
only needed by Xen fully virtualized
domains. <span class="since">Since 0.1.0</span></dd><dt><code>boot</code></dt><dd>The <code>dev</code> attribute takes one of the values "fd", "hd",
"cdrom" or "network" and is used to specify the next boot device
to consider. The <code>boot</code> element can be repeated multiple
times to setup a priority list of boot devices to try in turn. The
<code>boot</code> element cannot be used if per-device boot elements
are used (see <a href="#elementsDisks">disks</a>,
<a href="#elementsNICS">network interfaces</a>, and
<a href="#elementsUSB">USB and PCI devices</a> sections below).
<span class="since">Since 0.1.3, per-device boot since 0.8.8</span>
</dd><dt><code>bootmenu</code></dt><dd> Whether or not to enable an interactive boot menu prompt on guest
startup. The <code>enable</code> attribute can be either "yes" or "no".
If not specified, the hypervisor default is used. <span class="since">
Since 0.8.3</span>
</dd><dt><code>smbios</code></dt><dd>How to populate SMBIOS information visible in the guest.
The <code>mode</code> attribute must be specified, and is either
"emulate" (let the hypervisor generate all values), "host" (copy
all of Block 0 and Block 1, except for the UUID, from the host's
SMBIOS values;
the <a href="html/libvirt-libvirt.html#virConnectGetSysinfo">
<code>virConnectGetSysinfo</code></a> call can be
used to see what values are copied), or "sysinfo" (use the values in
the <a href="#elementsSysinfo">sysinfo</a> element). If not
specified, the hypervisor default is used. <span class="since">
Since 0.8.7</span>
</dd><dt><code>bios</code></dt><dd>This element has attribute <code>useserial</code> with possible
values <code>yes</code> or <code>no</code>. It enables or disables
Serial Graphics Adapter which allows users to see BIOS messages
on a serial port. Therefore, one needs to have
<a href="#elementCharSerial">serial port</a> defined.
<span class="since">Since 0.9.4</span>
</dd></dl>
<h4>
<a name="elementsOSBootloader" id="elementsOSBootloader">Host bootloader</a>
</h4>
<p>
Hypervisors employing paravirtualization do not usually emulate
a BIOS, and instead the host is responsible to kicking off the
operating system boot. This may use a pseudo-bootloader in the
host to provide an interface to choose a kernel for the guest.
An example is <code>pygrub</code> with Xen.
</p>
<pre>
...
<bootloader>/usr/bin/pygrub</bootloader>
<bootloader_args>--append single</bootloader_args>
...</pre>
<dl><dt><code>bootloader</code></dt><dd>The content of the <code>bootloader</code> element provides
a fully qualified path to the bootloader executable in the
host OS. This bootloader will be run to choose which kernel
to boot. The required output of the bootloader is dependent
on the hypervisor in use. <span class="since">Since 0.1.0</span></dd><dt><code>bootloader_args</code></dt><dd>The optional <code>bootloader_args</code> element allows
command line arguments to be passed to the bootloader.
<span class="since">Since 0.2.3</span>
</dd></dl>
<h4>
<a name="elementsOSKernel" id="elementsOSKernel">Direct kernel boot</a>
</h4>
<p>
When installing a new guest OS it is often useful to boot directly
from a kernel and initrd stored in the host OS, allowing command
line arguments to be passed directly to the installer. This capability
is usually available for both para and full virtualized guests.
</p>
<pre>
...
<os>
<type>hvm</type>
<loader>/usr/lib/xen/boot/hvmloader</loader>
<kernel>/root/f8-i386-vmlinuz</kernel>
<initrd>/root/f8-i386-initrd</initrd>
<cmdline>console=ttyS0 ks=http://example.com/f8-i386/os/</cmdline>
</os>
...</pre>
<dl><dt><code>type</code></dt><dd>This element has the same semantics as described earlier in the
<a href="#elementsOSBIOS">BIOS boot section</a></dd><dt><code>loader</code></dt><dd>This element has the same semantics as described earlier in the
<a href="#elementsOSBIOS">BIOS boot section</a></dd><dt><code>kernel</code></dt><dd>The contents of this element specify the fully-qualified path
to the kernel image in the host OS.</dd><dt><code>initrd</code></dt><dd>The contents of this element specify the fully-qualified path
to the (optional) ramdisk image in the host OS.</dd><dt><code>cmdline</code></dt><dd>The contents of this element specify arguments to be passed to
the kernel (or installer) at boottime. This is often used to
specify an alternate primary console (eg serial port), or the
installation media source / kickstart file</dd></dl>
<h3>
<a name="elementsSysinfo" id="elementsSysinfo">SMBIOS System Information</a>
</h3>
<p>
Some hypervisors allow control over what system information is
presented to the guest (for example, SMBIOS fields can be
populated by a hypervisor and inspected via
the <code>dmidecode</code> command in the guest). The
optional <code>sysinfo</code> element covers all such categories
of information. <span class="since">Since 0.8.7</span>
</p>
<pre>
...
<os>
<smbios mode='sysinfo'/>
...
</os>
<sysinfo type='smbios'>
<bios>
<entry name='vendor'>LENOVO</entry>
</bios>
<system>
<entry name='manufacturer'>Fedora</entry>
<entry name='vendor'>Virt-Manager</entry>
</system>
</sysinfo>
...</pre>
<p>
The <code>sysinfo</code> element has a mandatory
attribute <code>type</code> that determine the layout of
sub-elements, with supported values of:
</p>
<dl><dt><code>smbios</code></dt><dd>Sub-elements call out specific SMBIOS values, which will
affect the guest if used in conjunction with
the <code>smbios</code> sub-element of
the <a href="#elementsOS"><code>os</code></a> element. Each
sub-element of <code>sysinfo</code> names a SMBIOS block, and
within those elements can be a list of <code>entry</code>
elements that describe a field within the block. The following
blocks and entries are recognized:
<dl><dt><code>bios</code></dt><dd>
This is block 0 of SMBIOS, with entry names drawn from
"vendor", "version", "date", and "release".
</dd><dt><code>system</code></dt><dd>
This is block 1 of SMBIOS, with entry names drawn from
"manufacturer", "product", "version", "serial", "uuid",
"sku", and "family". If a "uuid" entry is provided
alongside a
top-level <a href="#elementsMetadata"><code>uuid</code>
element</a>, the two values must match.
</dd></dl></dd></dl>
<h3>
<a name="elementsCPUAllocation" id="elementsCPUAllocation">CPU Allocation</a>
</h3>
<pre>
<domain>
...
<vcpu cpuset="1-4,^3,6" current="1">2</vcpu>
...
</domain>
</pre>
<dl><dt><code>vcpu</code></dt><dd>The content of this element defines the maximum number of virtual
CPUs allocated for the guest OS, which must be between 1 and
the maximum supported by the hypervisor. <span class="since">Since
0.4.4</span>, this element can contain an optional
<code>cpuset</code> attribute, which is a comma-separated
list of physical CPU numbers that virtual CPUs can be pinned
to. Each element in that list is either a single CPU number,
a range of CPU numbers, or a caret followed by a CPU number to
be excluded from a previous range. <span class="since">Since
0.8.5</span>, the optional attribute <code>current</code> can
be used to specify whether fewer than the maximum number of
virtual CPUs should be enabled.
</dd></dl>
<h3>
<a name="elementsCPUTuning" id="elementsCPUTuning">CPU Tuning</a>
</h3>
<pre>
<domain>
...
<cputune>
<vcpupin vcpu="0" cpuset="1-4,^2"/>
<vcpupin vcpu="1" cpuset="0,1"/>
<vcpupin vcpu="2" cpuset="2,3"/>
<vcpupin vcpu="3" cpuset="0,4"/>
<shares>2048</shares>
<period>1000000</period>
<quota>-1</quota>
</cputune>
...
</domain>
</pre>
<dl><dt><code>cputune</code></dt><dd>
The optional <code>cputune</code> element provides details
regarding the cpu tunable parameters for the domain.
<span class="since">Since 0.9.0</span>
</dd><dt><code>vcpupin</code></dt><dd>
The optional <code>vcpupin</code> element specifies which of host
physical CPUS the domain VCPU will be pinned to. If this is ommited,
each VCPU pinned to all the physical CPUS by default. It contains two
required attributes, the attribute <code>vcpu</code> specifies vcpu id,
and the attribute <code>cpuset</code> is same as
attribute <code>cpuset</code>
of element <code>vcpu</code>. (NB: Only qemu driver support)
<span class="since">Since 0.9.0</span>
</dd><dt><code>shares</code></dt><dd>
The optional <code>shares</code> element specifies the proportional
weighted share for the domain. If this is ommited, it defaults to
the OS provided defaults. NB, There is no unit for the value,
it's a relative measure based on the setting of other VM,
e.g. A VM configured with value
2048 will get twice as much CPU time as a VM configured with value 1024.
<span class="since">Since 0.9.0</span>
</dd><dt><code>period</code></dt><dd>
The optional <code>period</code> element specifies the enforcement
interval(unit: microseconds). Within <code>period</code>, each vcpu of
the domain will not be allowed to consume more than <code>quota</code>
worth of runtime. The value should be in range [1000, 1000000]. A period
with value 0 means no value. (NB: Only qemu driver support)
<span class="since">Since 0.9.4</span>
</dd><dt><code>quota</code></dt><dd>
The optional <code>quota</code> element specifies the maximum allowed
bandwidth(unit: microseconds). A domain with <code>quota</code> as any
negative value indicates that the domain has infinite bandwidth, which
means that it is not bandwidth controlled. The value should be in range
[1000, 18446744073709551] or less than 0. A quota with value 0 means no
value. You can use this feature to ensure that all vcpus run at the same
speed. (NB: Only qemu driver support)
<span class="since">Since 0.9.4</span>
</dd></dl>
<h3>
<a name="elementsMemoryAllocation" id="elementsMemoryAllocation">Memory Allocation</a>
</h3>
<pre>
<domain>
...
<memory>524288</memory>
<currentMemory>524288</currentMemory>
...
</domain>
</pre>
<dl><dt><code>memory</code></dt><dd>The maximum allocation of memory for the guest at boot time.
The units for this value are kilobytes (i.e. blocks of 1024 bytes)</dd><dt><code>currentMemory</code></dt><dd>The actual allocation of memory for the guest. This value can
be less than the maximum allocation, to allow for ballooning
up the guests memory on the fly. If this is omitted, it defaults
to the same value as the <code>memory</code> element</dd></dl>
<h3>
<a name="elementsMemoryBacking" id="elementsMemoryBacking">Memory Backing</a>
</h3>
<pre>
<domain>
...
<memoryBacking>
<hugepages/>
</memoryBacking>
...
</domain>
</pre>
<dl><dt><code>memoryBacking</code></dt><dd>The optional <code>memoryBacking</code> element, may have an
<code>hugepages</code> element set within it. This tells the
hypervisor that the guest should have its memory allocated using
hugepages instead of the normal native page size.</dd></dl>
<h3>
<a name="elementsMemoryTuning" id="elementsMemoryTuning">Memory Tuning</a>
</h3>
<pre>
<domain>
...
<memtune>
<hard_limit>1048576</hard_limit>
<soft_limit>131072</soft_limit>
<swap_hard_limit>2097152</swap_hard_limit>
<min_guarantee>65536</min_guarantee>
</memtune>
...
</domain>
</pre>
<dl><dt><code>memtune</code></dt><dd> The optional <code>memtune</code> element provides details
regarding the memory tunable parameters for the domain. If this is
omitted, it defaults to the OS provided defaults. For QEMU/KVM, the
parameters are applied to the QEMU process as a whole. Thus, when
counting them, one needs to add up guest RAM, guest video RAM, and
some memory overhead of QEMU itself. The last piece is hard to
determine so one needs guess and try.</dd><dt><code>hard_limit</code></dt><dd> The optional <code>hard_limit</code> element is the maximum memory
the guest can use. The units for this value are kilobytes (i.e. blocks
of 1024 bytes)</dd><dt><code>soft_limit</code></dt><dd> The optional <code>soft_limit</code> element is the memory limit to
enforce during memory contention. The units for this value are
kilobytes (i.e. blocks of 1024 bytes)</dd><dt><code>swap_hard_limit</code></dt><dd> The optional <code>swap_hard_limit</code> element is the maximum
memory plus swap the guest can use. The units for this value are
kilobytes (i.e. blocks of 1024 bytes). This has to be more than
hard_limit value provided</dd><dt><code>min_guarantee</code></dt><dd> The optional <code>min_guarantee</code> element is the guaranteed
minimum memory allocation for the guest. The units for this value are
kilobytes (i.e. blocks of 1024 bytes)</dd></dl>
<h3>
<a name="elementsNUMATuning" id="elementsNUMATuning">NUMA Node Tuning</a>
</h3>
<pre>
<domain>
...
<numatune>
<memory mode="strict" nodeset="1-4,^3"/>
</numatune>
...
</domain>
</pre>
<dl><dt><code>numatune</code></dt><dd>
The optional <code>numatune</code> element provides details of
how to tune the performance of a NUMA host via controlling NUMA policy
for domain process. NB, only supported by QEMU driver.
<span class="since">Since 0.9.3</span>
</dd><dt><code>memory</code></dt><dd>
The optional <code>memory</code> element specify how to allocate memory
for the domain process on a NUMA host. It contains two attributes,
attribute <code>mode</code> is either 'interleave', 'strict',
or 'preferred',
attribute <code>nodeset</code> specifies the NUMA nodes, it leads same
syntax with attribute <code>cpuset</code> of element <code>vcpu</code>.
<span class="since">Since 0.9.3</span>
</dd></dl>
<h3>
<a name="elementsBlockTuning" id="elementsBlockTuning">Block I/O Tuning</a>
</h3>
<pre>
<domain>
...
<blkiotune>
<weight>800</weight>
<device>
<path>/dev/sda</path>
<weight>1000</weight>
</device>
<device>
<path>/dev/sdb</path>
<weight>500</weight>
</device>
</blkiotune>
...
</domain>
</pre>
<dl><dt><code>blkiotune</code></dt><dd> The optional <code>blkiotune</code> element provides the ability
to tune Blkio cgroup tunable parameters for the domain. If this is
omitted, it defaults to the OS provided
defaults. <span class="since">Since 0.8.8</span></dd><dt><code>weight</code></dt><dd> The optional <code>weight</code> element is the overall I/O
weight of the guest. The value should be in the range [100,
1000].</dd><dt><code>device</code></dt><dd>The domain may have multiple <code>device</code> elements
that further tune the weights for each host block device in
use by the domain. Note that
multiple <a href="#elementsDisks">guest disks</a> can share a
single host block device, if they are backed by files within
the same host file system, which is why this tuning parameter
is at the global domain level rather than associated with each
guest disk device (contrast this to
the <a href="#elementsDisks"><code><iotune></code></a>
element which can apply to an
individual <code><disk></code>).
Each <code>device</code> element has two
mandatory sub-elements, <code>path</code> describing the
absolute path of the device, and <code>weight</code> giving
the relative weight of that device, in the range [100,
1000]. <span class="since">Since 0.9.8</span></dd></dl>
<h3>
<a name="elementsCPU" id="elementsCPU">CPU model and topology</a>
</h3>
<p>
Requirements for CPU model, its features and topology can be specified
using the following collection of elements.
<span class="since">Since 0.7.5</span>
</p>
<pre>
...
<cpu match='exact'>
<model>core2duo</model>
<vendor>Intel</vendor>
<topology sockets='1' cores='2' threads='1'/>
<feature policy='disable' name='lahf_lm'/>
</cpu>
...</pre>
<p>
In case no restrictions need to be put on CPU model and its features, a
simpler <code>cpu</code> element can be used.
<span class="since">Since 0.7.6</span>
</p>
<pre>
...
<cpu>
<topology sockets='1' cores='2' threads='1'/>
</cpu>
...</pre>
<dl><dt><code>cpu</code></dt><dd>The <code>cpu</code> element is the main container for describing
guest CPU requirements. Its <code>match</code> attribute specified how
strictly has the virtual CPU provided to the guest match these
requirements. <span class="since">Since 0.7.6</span> the
<code>match</code> attribute can be omitted if <code>topology</code>
is the only element within <code>cpu</code>. Possible values for the
<code>match</code> attribute are:
<dl><dt><code>minimum</code></dt><dd>The specified CPU model and features describes the minimum
requested CPU.</dd><dt><code>exact</code></dt><dd>The virtual CPU provided to the guest will exactly match the
specification</dd><dt><code>strict</code></dt><dd>The guest will not be created unless the host CPU does exactly
match the specification.</dd></dl><span class="since">Since 0.8.5</span> the <code>match</code>
attribute can be omitted and will default to <code>exact</code>.
</dd><dt><code>model</code></dt><dd>The content of the <code>model</code> element specifies CPU model
requested by the guest. The list of available CPU models and their
definition can be found in <code>cpu_map.xml</code> file installed
in libvirt's data directory.</dd><dt><code>vendor</code></dt><dd><span class="since">Since 0.8.3</span> the content of the
<code>vendor</code> element specifies CPU vendor requested by the
guest. If this element is missing, the guest can be run on a CPU
matching given features regardless on its vendor. The list of
supported vendors can be found in <code>cpu_map.xml</code>.</dd><dt><code>topology</code></dt><dd>The <code>topology</code> element specifies requested topology of
virtual CPU provided to the guest. Three non-zero values have to be
given for <code>sockets</code>, <code>cores</code>, and
<code>threads</code>: total number of CPU sockets, number of cores per
socket, and number of threads per core, respectively.</dd><dt><code>feature</code></dt><dd>The <code>cpu</code> element can contain zero or more
<code>elements</code> used to fine-tune features provided by the
selected CPU model. The list of known feature names can be found in
the same file as CPU models. The meaning of each <code>feature</code>
element depends on its <code>policy</code> attribute, which has to be
set to one of the following values:
<dl><dt><code>force</code></dt><dd>The virtual CPU will claim the feature is supported regardless
of it being supported by host CPU.</dd><dt><code>require</code></dt><dd>Guest creation will fail unless the feature is supported by host
CPU.</dd><dt><code>optional</code></dt><dd>The feature will be supported by virtual CPU if and only if it
is supported by host CPU.</dd><dt><code>disable</code></dt><dd>The feature will not be supported by virtual CPU.</dd><dt><code>forbid</code></dt><dd>Guest creation will fail if the feature is supported by host
CPU.</dd></dl><span class="since">Since 0.8.5</span> the <code>policy</code>
attribute can be omitted and will default to <code>require</code>.
</dd></dl>
<p>
Guest NUMA topology can be specifed using the <code>numa</code> element.
<span class="since">Since 0.9.8</span>
</p>
<pre>
...
<cpu>
...
<numa>
<cell cpus='0-3' memory='512000'/>
<cell cpus='4-7' memory='512000'/>
</numa>
...
</cpu>
...</pre>
<p>
Each <code>cell</code> element specifies a NUMA cell or a NUMA node.
<code>cpus</code> specifies the CPU or range of CPUs that are part of
the node. <code>memory</code> specifies the node memory in kilobytes
(i.e. blocks of 1024 bytes). Each cell or node is assigned cellid
or nodeid in the increasing order starting from 0.
</p>
<p>
This guest NUMA specification is currently available only for QEMU/KVM.
</p>
<h3>
<a name="elementsLifecycle" id="elementsLifecycle">Lifecycle control</a>
</h3>
<p>
It is sometimes necessary to override the default actions taken
when a guest OS triggers a lifecycle operation. The following
collections of elements allow the actions to be specified. A
common use case is to force a reboot to be treated as a poweroff
when doing the initial OS installation. This allows the VM to be
re-configured for the first post-install bootup.
</p>
<pre>
...
<on_poweroff>destroy</on_poweroff>
<on_reboot>restart</on_reboot>
<on_crash>restart</on_crash>
...</pre>
<dl><dt><code>on_poweroff</code></dt><dd>The content of this element specifies the action to take when
the guest requests a poweroff.</dd><dt><code>on_reboot</code></dt><dd>The content of this element specifies the action to take when
the guest requests a reboot.</dd><dt><code>on_crash</code></dt><dd>The content of this element specifies the action to take when
the guest crashes.</dd></dl>
<p>
Each of these states allow for the same four possible actions.
</p>
<dl><dt><code>destroy</code></dt><dd>The domain will be terminated completely and all resources
released</dd><dt><code>restart</code></dt><dd>The domain will be terminated, and then restarted with
the same configuration</dd><dt><code>preserve</code></dt><dd>The domain will be terminated, and its resource preserved
to allow analysis.</dd><dt><code>rename-restart</code></dt><dd>The domain will be terminated, and then restarted with
a new name</dd></dl>
<p>
on_crash supports these additional
actions <span class="since">since 0.8.4</span>.
</p>
<dl><dt><code>coredump-destroy</code></dt><dd>The crashed domain's core will be dumped, and then the
domain will be terminated completely and all resources
released</dd><dt><code>coredump-restart</code></dt><dd>The crashed domain's core will be dumped, and then the
domain will be restarted with the same configuration</dd></dl>
<h3>
<a name="elementsFeatures" id="elementsFeatures">Hypervisor features</a>
</h3>
<p>
Hypervisors may allow certain CPU / machine features to be
toggled on/off.
</p>
<pre>
...
<features>
<pae/>
<acpi/>
<apic/>
<hap/>
</features>
...</pre>
<p>
All features are listed within the <code>features</code>
element, omitting a togglable feature tag turns it off.
The available features can be found by asking
for the <a href="formatcaps.html">capabilities XML</a>,
but a common set for fully virtualized domains are:
</p>
<dl><dt><code>pae</code></dt><dd>Physical address extension mode allows 32-bit guests
to address more than 4 GB of memory.</dd><dt><code>acpi</code></dt><dd>ACPI is useful for power management, for example, with
KVM guests it is required for graceful shutdown to work.
</dd><dt><code>hap</code></dt><dd>Enable use of Hardware Assisted Paging if available in
the hardware.
</dd></dl>
<h3>
<a name="elementsTime" id="elementsTime">Time keeping</a>
</h3>
<p>
The guest clock is typically initialized from the host clock.
Most operating systems expect the hardware clock to be kept
in UTC, and this is the default. Windows, however, expects
it to be in so called 'localtime'.
</p>
<pre>
...
<clock offset="localtime">
<timer name="rtc" tickpolicy="catchup" track="guest">
<catchup threshold=123 slew=120 limit=10000/>
</timer>
<timer name="pit" tickpolicy="delay"/>
</clock>
...</pre>
<dl><dt><code>clock</code></dt><dd>
<p>The <code>offset</code> attribute takes four possible
values, allowing fine grained control over how the guest
clock is synchronized to the host. NB, not all hypervisors
support all modes.</p>
<dl><dt><code>utc</code></dt><dd>
The guest clock will always be synchronized to UTC when
booted</dd><dt><code>localtime</code></dt><dd>
The guest clock will be synchronized to the host's configured
timezone when booted, if any.
</dd><dt><code>timezone</code></dt><dd>
The guest clock will be synchronized to the requested timezone
using the <code>timezone</code> attribute.
<span class="since">Since 0.7.7</span>
</dd><dt><code>variable</code></dt><dd>
The guest clock will have an arbitrary offset applied
relative to UTC. The delta relative to UTC is specified
in seconds, using the <code>adjustment</code> attribute.
The guest is free to adjust the RTC over time and expect
that it will be honoured at next reboot. This is in
contrast to 'utc' mode, where the RTC adjustments are
lost at each reboot. <span class="since">Since 0.7.7</span>
</dd></dl><p>
A <code>clock</code> may have zero or more
<code>timer</code>sub-elements. <span class="since">Since
0.8.0</span>
</p>
</dd><dt><code>timer</code></dt><dd>
<p>
Each timer element requires a <code>name</code> attribute,
and has other optional attributes that depend on
the <code>name</code> specified. Various hypervisors
support different combinations of attributes.
</p>
<dl><dt><code>name</code></dt><dd>
The <code>name</code> attribute selects which timer is
being modified, and can be one of "platform", "pit",
"rtc", "hpet", or "tsc".
</dd><dt><code>track</code></dt><dd>
The <code>track</code> attribute specifies what the timer
tracks, and can be "boot", "guest", or "wall".
Only valid for <code>name="rtc"</code>
or <code>name="platform"</code>.
</dd><dt><code>tickpolicy</code></dt><dd>
The <code>tickpolicy</code> attribute determines how
missed ticks in the guest are handled, and can be "delay",
"catchup", "merge", or "discard". If the policy is
"catchup", there can be further details in
the <code>catchup</code> sub-element.
<dl><dt><code>catchup</code></dt><dd>
The <code>catchup</code> element has three optional
attributes, each a positive integer. The attributes
are <code>threshold</code>, <code>slew</code>,
and <code>limit</code>.
</dd></dl></dd><dt><code>frequency</code></dt><dd>
The <code>frequency</code> attribute is an unsigned
integer specifying the frequency at
which <code>name="tsc"</code> runs.
</dd><dt><code>mode</code></dt><dd>
The <code>mode</code> attribute controls how
the <code>name="tsc"</code> timer is managed, and can be
"auto", "native", "emulate", "paravirt", or "smpsafe".
Other timers are always emulated.
</dd><dt><code>present</code></dt><dd>
The <code>present</code> attribute can be "yes" or "no" to
specify whether a particular timer is available to the guest.
</dd></dl></dd></dl>
<h3>
<a name="elementsDevices" id="elementsDevices">Devices</a>
</h3>
<p>
The final set of XML elements are all used to describe devices
provided to the guest domain. All devices occur as children
of the main <code>devices</code> element.
<span class="since">Since 0.1.3</span>
</p>
<pre>
...
<devices>
<emulator>/usr/lib/xen/bin/qemu-dm</emulator>
</devices>
...</pre>
<dl><dt><code>emulator</code></dt><dd>
The contents of the <code>emulator</code> element specify
the fully qualified path to the device model emulator binary.
The <a href="formatcaps.html">capabilities XML</a> specifies
the recommended default emulator to use for each particular
domain type / architecture combination.
</dd></dl>
<h4>
<a name="elementsDisks" id="elementsDisks">Hard drives, floppy disks, CDROMs</a>
</h4>
<p>
Any device that looks like a disk, be it a floppy, harddisk,
cdrom, or paravirtualized driver is specified via the <code>disk</code>
element.
</p>
<pre>
...
<devices>
<disk type='file' snapshot='external'>
<driver name="tap" type="aio" cache="default"/>
<source file='/var/lib/xen/images/fv0'/ startupPolicy='optional'>
<target dev='hda' bus='ide'/>
<iotune>
<total_bytes_sec>10000000</total_bytes_sec>
<read_iops_sec>400000</read_iops_sec>
<write_iops_sec>100000</write_iops_sec>
</iotune>
<boot order='2'/>
<encryption type='...'>
...
</encryption>
<shareable/>
<serial>
...
</serial>
</disk>
...
<disk type='network'>
<driver name="qemu" type="raw" io="threads" ioeventfd="on" event_idx="off"/>
<source protocol="sheepdog" name="image_name">
<host name="hostname" port="7000"/>
</source>
<target dev="hdb" bus="ide"/>
<boot order='1'/>
<transient/>
<address type='drive' controller='0' bus='1' unit='0'/>
</disk>
<disk type='network'>
<driver name="qemu" type="raw"/>
<source protocol="rbd" name="image_name2">
<host name="hostname" port="7000"/>
</source>
<target dev="hdd" bus="ide"/>
<auth username='myuser'>
<secret type='ceph' usage='mypassid'/>
</auth>
</disk>
<disk type='block' device='cdrom'>
<driver name='qemu' type='raw'/>
<target dev='hdc' bus='ide'/>
<readonly/>
</disk>
</devices>
...</pre>
<dl><dt><code>disk</code></dt><dd>The <code>disk</code> element is the main container for describing
disks. The <code>type</code> attribute is either "file",
"block", "dir", or "network"
and refers to the underlying source for the disk. The optional
<code>device</code> attribute indicates how the disk is to be exposed
to the guest OS. Possible values for this attribute are "floppy", "disk"
and "cdrom", defaulting to "disk". The
optional <code>snapshot</code> attribute indicates the default
behavior of the disk during disk snapshots: "internal"
requires a file format such as qcow2 that can store both the
snapshot and the data changes since the snapshot;
"external" will separate the snapshot from the live data; and
"no" means the disk will not participate in snapshots.
Read-only disks default to "no", while the default for other
disks depends on the hypervisor's capabilities. Some
hypervisors allow a per-snapshot choice as well,
during <a href="formatsnapshot.html">domain snapshot
creation</a>. Not all snapshot modes are supported;
for example, <code>snapshot='yes'</code> with a transient disk
generally does not make sense. <span class="since">Since 0.0.3;
"device" attribute since 0.1.4;
"network" attribute since 0.8.7; "snapshot" since
0.9.5</span></dd><dt><code>source</code></dt><dd>If the disk <code>type</code> is "file", then
the <code>file</code> attribute specifies the fully-qualified
path to the file holding the disk. If the disk
<code>type</code> is "block", then the <code>dev</code>
attribute specifies the path to the host device to serve as
the disk. If the disk <code>type</code> is "dir", then the
<code>dir</code> attribute specifies the fully-qualified path
to the directory to use as the disk. If the disk <code>type</code>
is "network", then the <code>protocol</code> attribute specifies
the protocol to access to the requested image; possible values
are "nbd", "rbd", and "sheepdog". If the <code>protocol</code>
attribute is "rbd" or "sheepdog", an additional
attribute <code>name</code> is mandatory to specify which
image to be used. When the disk <code>type</code> is
"network", the <code>source</code> may have zero or
more <code>host</code> sub-elements used to specify the hosts
to connect.
<span class="since">Since 0.0.3; <code>type='dir'</code> since
0.7.5; <code>type='network'</code> since 0.8.7</span><br />
For a "file" disk type which represents a cdrom or floppy
(the <code>device</code> attribute), it is possible to define
policy what to do with the disk if the source file is not accessible.
This is done by the <code>startupPolicy</code> attribute, accepting
these values:
<table class="top_table"><tr><td> mandatory </td><td> fail if missing for any reason (the default) </td></tr><tr><td> requisite </td><td> fail if missing on boot up,
drop if missing on migrate/restore/revert </td></tr><tr><td> optional </td><td> drop if missing at any start attempt </td></tr></table><span class="since">Since 0.9.7</span>
</dd><dt><code>target</code></dt><dd>The <code>target</code> element controls the bus / device
under which the disk is exposed to the guest
OS. The <code>dev</code> attribute indicates the "logical"
device name. The actual device name specified is not
guaranteed to map to the device name in the guest OS. Treat it
as a device ordering hint. The optional <code>bus</code>
attribute specifies the type of disk device to emulate;
possible values are driver specific, with typical values being
"ide", "scsi", "virtio", "xen", "usb" or "sata". If omitted, the bus
type is inferred from the style of the device name. eg, a device named
'sda' will typically be exported using a SCSI bus.
<span class="since">Since 0.0.3; <code>bus</code> attribute since 0.4.3;
"usb" attribute value since after 0.4.4; "sata" attribute value since
0.9.7</span></dd><dt><code>iotune</code></dt><dd>The optional <code>iotune</code> element provides the
ability to provide additional per-device I/O tuning, with
values that can vary for each device (contrast this to
the <a href="#elementsBlockTuning"><code><blkiotune></code></a>
element, which applies globally to the domain). Currently,
the only tuning available is Block I/O throttling for qemu.
This element has optional sub-elements; any sub-element not
specified or given with a value of 0 implies no
limit. <span class="since">Since 0.9.8</span>
<dl><dt><code>total_bytes_sec</code></dt><dd>The optional <code>total_bytes_sec</code> element is the
total throughput limit in bytes per second. This cannot
appear with <code>read_bytes_sec</code>
or <code>write_bytes_sec</code>.</dd><dt><code>read_bytes_sec</code></dt><dd>The optional <code>read_bytes_sec</code> element is the
read throughput limit in bytes per second.</dd><dt><code>write_bytes_sec</code></dt><dd>The optional <code>write_bytes_sec</code> element is the
write throughput limit in bytes per second.</dd><dt><code>total_iops_sec</code></dt><dd>The optional <code>total_iops_sec</code> element is the
total I/O operations per second. This cannot
appear with <code>read_iops_sec</code>
or <code>write_iops_sec</code>.</dd><dt><code>read_iops_sec</code></dt><dd>The optional <code>read_iops_sec</code> element is the
read I/O operations per second.</dd><dt><code>write_iops_sec</code></dt><dd>The optional <code>write_iops_sec</code> element is the
write I/O operations per second.</dd></dl></dd><dt><code>driver</code></dt><dd>
The optional driver element allows specifying further details
related to the hypervisor driver used to provide the disk.
<span class="since">Since 0.1.8</span>
<ul><li>
If the hypervisor supports multiple backend drivers, then
the <code>name</code> attribute selects the primary
backend driver name, while the optional <code>type</code>
attribute provides the sub-type. For example, xen
supports a name of "tap", "tap2", "phy", or "file", with a
type of "aio", while qemu only supports a name of "qemu",
but multiple types including "raw", "bochs", "qcow2", and
"qed".
</li><li>
The optional <code>cache</code> attribute controls the
cache mechanism, possible values are "default", "none",
"writethrough", "writeback", "directsync" (like
"writethrough", but it bypasses the host page cache) and
"unsafe" (host may cache all disk io, and sync requests from
guest are ignored).
<span class="since">
Since 0.6.0,
"directsync" since 0.9.5,
"unsafe" since 0.9.7
</span>
</li><li>
The optional <code>error_policy</code> attribute controls
how the hypervisor will behave on a disk read or write
error, possible values are "stop", "report", "ignore", and
"enospace".<span class="since">Since 0.8.0, "report" since
0.9.7</span> The default setting of error_policy is "report".
There is also an
optional <code>rerror_policy</code> that controls behavior
for read errors only. <span class="since">Since
0.9.7</span>. If no rerror_policy is given, error_policy
is used for both read and write errors. If rerror_policy
is given, it overrides the <code>error_policy</code> for
read errors. Also note that "enospace" is not a valid
policy for read errors, so if <code>error_policy</code> is
set to "enospace" and no <code>rerror_policy</code> is
given, the read error policy will be left at its default,
which is "report".
</li><li>
The optional <code>io</code> attribute controls specific
policies on I/O; qemu guests support "threads" and
"native". <span class="since">Since 0.8.8</span>
</li><li>
The optional <code>ioeventfd</code> attribute allows users to
set <a href="https://patchwork.kernel.org/patch/43390/">
domain I/O asynchronous handling</a> for disk device.
The default is left to the discretion of the hypervisor.
Accepted values are "on" and "off". Enabling this allows
qemu to execute VM while a separate thread handles I/O.
Typically guests experiencing high system CPU utilization
during I/O will benefit from this. On the other hand,
on overloaded host it could increase guest I/O latency.
<span class="since">Since 0.9.3 (QEMU and KVM only)</span>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</li><li>
The optional <code>event_idx</code> attribute controls
some aspects of device event processing. The value can be
either 'on' or 'off' - if it is on, it will reduce the
number of interupts and exits for the guest. The default
is determined by QEMU; usually if the feature is
supported, default is on. In case there is a situation
where this behavior is suboptimal, this attribute provides
a way to force the feature off.
<span class="since">Since 0.9.5 (QEMU and KVM only)</span>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</li></ul></dd><dt><code>boot</code></dt><dd>Specifies that the disk is bootable. The <code>order</code>
attribute determines the order in which devices will be tried during
boot sequence. The per-device <code>boot</code> elements cannot be
used together with general boot elements in
<a href="#elementsOSBIOS">BIOS bootloader</a> section.
<span class="since">Since 0.8.8</span>
</dd><dt><code>encryption</code></dt><dd>If present, specifies how the volume is encrypted. See
the <a href="formatstorageencryption.html">Storage Encryption</a> page
for more information.
</dd><dt><code>readonly</code></dt><dd>If present, this indicates the device cannot be modified by
the guest. For now, this is the default for disks with
attribute <code>type='cdrom'</code>.
</dd><dt><code>shareable</code></dt><dd>If present, this indicates the device is expected to be shared
between domains (assuming the hypervisor and OS support this),
which means that caching should be deactivated for that device.
</dd><dt><code>transient</code></dt><dd>If present, this indicates that changes to the device
contents should be reverted automatically when the guest
exits. With some hypervisors, marking a disk transient
prevents the domain from participating in migration or
snapshots. <span class="since">Since 0.9.5</span>
</dd><dt><code>serial</code></dt><dd>If present, this specify serial number of virtual hard drive.
For example, it may look
like <code><serial>WD-WMAP9A966149</serial></code>.
<span class="since">Since 0.7.1</span>
</dd><dt><code>host</code></dt><dd>The <code>host</code> element has two attributes "name" and "port",
which specify the hostname and the port number. The meaning of this
element and the number of the elements depend on the protocol attribute.
<table class="top_table"><tr><th> Protocol </th><th> Meaning </th><th> Number of hosts </th></tr><tr><td> nbd </td><td> a server running nbd-server </td><td> only one </td></tr><tr><td> rbd </td><td> monitor servers of RBD </td><td> one or more </td></tr><tr><td> sheepdog </td><td> one of the sheepdog servers (default is localhost:7000) </td><td> zero or one </td></tr></table></dd><dt><code>address</code></dt><dd>If present, the <code>address</code> element ties the disk
to a given slot of a controller (the
actual <code><controller></code> device can often be
inferred by libvirt, although it can
be <a href="#elementsControllers">explicitly specified</a>).
The <code>type</code> attribute is mandatory, and is typically
"pci" or "drive". For a "pci" controller, additional
attributes for <code>bus</code>, <code>slot</code>,
and <code>function</code> must be present, as well as
optional <code>domain</code> and <code>multifunction</code>.
Multifunction defaults to 'off'; any other value requires
QEMU 0.1.3 and <span class="since">libvirt 0.9.7</span>. For a
"drive" controller, additional attributes
<code>controller</code>, <code>bus</code>,
and <code>unit</code> are available, each defaulting to 0.
</dd><dt><code>auth</code></dt><dd>If present, the <code>auth</code> element provides the
authentication credentials needed to access the source. It
includes a mandatory attribute <code>username</code>, which
identifies the username to use during authentication, as well
as a sub-element <code>secret</code> with mandatory
attribute <code>type</code>, to tie back to
a <a href="formatsecret.html">libvirt secret object</a> that
holds the actual password or other credentials (the domain XML
intentionally does not expose the password, only the reference
to the object that does manage the password). For now, the
only known secret <code>type</code> is "ceph", for Ceph RBD
network sources, and requires either an
attribute <code>uuid</code> with the UUID of the Ceph secret
object, or an attribute <code>usage</code> with the name
associated with the Ceph secret
object. <span class="since">libvirt 0.9.7</span>
</dd></dl>
<h4>
<a name="elementsFilesystems" id="elementsFilesystems">Filesystems</a>
</h4>
<p>
A directory on the host that can be accessed directly from the guest.
<span class="since">since 0.3.3, since 0.8.5 for QEMU/KVM</span>
</p>
<pre>
...
<devices>
<filesystem type='template'>
<source name='my-vm-template'/>
<target dir='/'/>
</filesystem>
<filesystem type='mount' accessmode='passthrough'>
<driver type='path'/>
<source dir='/export/to/guest'/>
<target dir='/import/from/host'/>
<readonly/>
</filesystem>
...
</devices>
...</pre>
<dl><dt><code>filesystem</code></dt><dd>
The filesystem attribute <code>type</code> specifies the type of the
<code>source</code>. The possible values are:
<dl><dt><code>type='mount'</code></dt><dd>
A host directory to mount in the guest. Used by LXC,
OpenVZ <span class="since">(since 0.6.2)</span>
and QEMU/KVM <span class="since">(since 0.8.5)</span>.
This is the default <code>type</code> if one is not specified.
This mode also has an optional
sub-element <code>driver</code>, with an
attribute <code>type='path'</code>
or <code>type='handle'</code> <span class="since">(since
0.9.7)</span>.
</dd><dt><code>type='template'</code></dt><dd>
OpenVZ filesystem template. Only used by OpenVZ driver.
</dd><dt><code>type='file'</code></dt><dd>
Currently unused.
</dd><dt><code>type='block'</code></dt><dd>
A host block device to mount in the guest. The filesystem
format will be autodetected. Only used by LXC driver
<span class="since">(since 0.9.5)</span>.
</dd></dl>
The filesystem block has an optional attribute <code>accessmode</code>
which specifies the security mode for accessing the source
<span class="since">(since 0.8.5)</span>. Currently this only works
with <code>type='mount'</code> for the QEMU/KVM driver. The possible
values are:
<dl><dt><code>accessmode='passthrough'</code></dt><dd>
The <code>source</code> is accessed with the permissions of the
user inside the guest. This is the default <code>accessmode</code> if
one is not specified.
<a href="http://lists.gnu.org/archive/html/qemu-devel/2010-05/msg02673.html">More info</a>
</dd><dt><code>accessmode='mapped'</code></dt><dd>
The <code>source</code> is accessed with the permissions of the
hypervisor (QEMU process).
<a href="http://lists.gnu.org/archive/html/qemu-devel/2010-05/msg02673.html">More info</a>
</dd><dt><code>accessmode='squash'</code></dt><dd>
Similar to 'passthrough', the exception is that failure of
privileged operations like 'chown' are ignored. This makes a
passthrough-like mode usable for people who run the hypervisor
as non-root.
<a href="http://lists.gnu.org/archive/html/qemu-devel/2010-09/msg00121.html">More info</a>
</dd></dl></dd><dt><code>source</code></dt><dd>
The resource on the host that is being accessed in the guest. The
<code>name</code> attribute must be used with
<code>type='template'</code>, and the <code>dir</code> attribute must
be used with <code>type='mount'</code>
</dd><dt><code>target</code></dt><dd>
Where the <code>source</code> can be accessed in the guest. For
most drivers this is an automatic mount point, but for QEMU/KVM
this is merely an arbitrary string tag that is exported to the
guest as a hint for where to mount.
</dd><dt><code>readonly</code></dt><dd>
An optional <code>readonly</code> attribute is available but currently
unused.
</dd></dl>
<h4>
<a name="elementsControllers" id="elementsControllers">Controllers</a>
</h4>
<p>
Many devices that have an <code><address></code>
sub-element are designed to work with a controller to manage
related devices. Normally, libvirt can automatically infer such
controllers without requiring explicit XML markup, but sometimes
it is necessary to provide an explicit controller element.
</p>
<pre>
...
<devices>
<controller type='ide' index='0'/>
<controller type='virtio-serial' index='0' ports='16' vectors='4'/>
<controller type='virtio-serial' index='1'>
<address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/>
</controller>
...
</devices>
...</pre>
<p>
Each controller has a mandatory attribute <code>type</code>,
which must be one of "ide", "fdc", "scsi", "sata", "usb",
"ccid", or "virtio-serial", and a mandatory
attribute <code>index</code> which is the decimal integer
describing in which order the bus controller is encountered (for
use in <code>controller</code> attributes
of <code><address></code> elements). The "virtio-serial"
controller has two additional optional
attributes <code>ports</code> and <code>vectors</code>, which
control how many devices can be connected through the
controller. A "scsi" controller has an optional
attribute <code>model</code>, which is one of "auto",
"buslogic", "lsilogic", "lsias1068", or "vmpvscsi".
A "usb" controller has an optional attribute <code>model</code>,
which is one of "piix3-uhci", "piix4-uhci", "ehci",
"ich9-ehci1", "ich9-uhci1", "ich9-uhci2", "ich9-uhci3",
"vt82c686b-uhci" or "pci-ohci".
</p>
<p>
For controllers that are themselves devices on a PCI or USB bus,
an optional sub-element <code><address></code> can specify
the exact relationship of the controller to its master bus, with
semantics like any other device's <code>address</code>
sub-element.
</p>
<p>
USB companion controllers have an optional
sub-element <code><master></code> to specify the exact
relationship of the companion to its master controller.
A companion controller is on the same bus as its master, so
the companion <code>index</code> value should be equal.
</p>
<pre>
...
<devices>
<controller type='usb' index='0' model='ich9-ehci1'>
<address type='pci' domain='0' bus='0' slot='4' function='7'/>
</controller>
<controller type='usb' index='0' model='ich9-uhci1'>
<master startport='0'/>
<address type='pci' domain='0' bus='0' slot='4' function='0' multifunction='on'/>
</controller>
...
</devices>
...</pre>
<h4>
<a name="elementsLease" id="elementsLease">Device leases</a>
</h4>
<p>
When using a lock manager, it may be desirable to record device leases
against a VM. The lock manager will ensure the VM won't start unless
the leases can be acquired.
</p>
<pre>
...
<devices>
...
<lease>
<lockspace>somearea</lockspace>
<key>somekey</key>
<target path='/some/lease/path' offset='1024'/>
</lease>
...
</devices>
...</pre>
<dl><dt>lockspace</dt><dd>This is an arbitrary string, identifying the lockspace
within which the key is held. Lock managers may impose
extra restrictions on the format, or length of the lockspace
name.</dd><dt>key</dt><dd>This is an arbitrary string, uniquely identifying the
lease to be acquired. Lock managers may impose extra
restrictions on the format, or length of the key.
</dd><dt>target</dt><dd>This is the fully qualified path of the file associated
with the lockspace. The offset specifies where the lease
is stored within the file. If the lock manager does not
require a offset, just pass 0.
</dd></dl>
<h4>
<a name="elementsUSB" id="elementsUSB">USB and PCI devices</a>
</h4>
<p>
USB and PCI devices attached to the host can be passed through
to the guest using
the <code>hostdev</code> element. <span class="since">since after
0.4.4 for USB and 0.6.0 for PCI (KVM only)</span>:
</p>
<pre>
...
<devices>
<hostdev mode='subsystem' type='usb'>
<source>
<vendor id='0x1234'/>
<product id='0xbeef'/>
</source>
<boot order='2'/>
</hostdev>
</devices>
...</pre>
<p>or:</p>
<pre>
...
<devices>
<hostdev mode='subsystem' type='pci' managed='yes'>
<source>
<address bus='0x06' slot='0x02' function='0x0'/>
</source>
<boot order='1'/>
<rom bar='off'/>
</hostdev>
</devices>
...</pre>
<dl><dt><code>hostdev</code></dt><dd>The <code>hostdev</code> element is the main container for describing
host devices. For usb device passthrough <code>mode</code> is always
"subsystem" and <code>type</code> is "usb" for a USB device and "pci"
for a PCI device. When <code>managed</code> is "yes" for a PCI
device, it is detached from the host before being passed on to
the guest, and reattached to the host after the guest exits.
If <code>managed</code> is omitted or "no", and for USB
devices, the user is responsible to
call <code>virNodeDeviceDettach</code> (or <code>virsh
nodedev-dettach</code>) before starting the guest or
hot-plugging the device,
and <code>virNodeDeviceReAttach</code> (or <code>virsh
nodedev-reattach</code>) after hot-unplug or stopping the
guest.</dd><dt><code>source</code></dt><dd>The source element describes the device as seen from the host.
The USB device can either be addressed by vendor / product id using the
<code>vendor</code> and <code>product</code> elements or by the device's
address on the hosts using the <code>address</code> element.
PCI devices on the other hand can only be described by their
<code>address</code></dd><dt><code>vendor</code>, <code>product</code></dt><dd>The <code>vendor</code> and <code>product</code> elements each have an
<code>id</code> attribute that specifies the USB vendor and product id.
The ids can be given in decimal, hexadecimal (starting with 0x) or
octal (starting with 0) form.</dd><dt><code>boot</code></dt><dd>Specifies that the device is bootable. The <code>order</code>
attribute determines the order in which devices will be tried during
boot sequence. The per-device <code>boot</code> elements cannot be
used together with general boot elements in
<a href="#elementsOSBIOS">BIOS bootloader</a> section.
<span class="since">Since 0.8.8</span></dd><dt><code>rom</code></dt><dd>The <code>rom</code> element is used to change how a PCI
device's ROM is presented to the guest. The <code>bar</code>
attribute can be set to "on" or "off", and determines whether
or not the device's ROM will be visible in the guest's memory
map. (In PCI documentation, the "rombar" setting controls the
presence of the Base Address Register for the ROM). If no rom
bar is specified, the qemu default will be used (older
versions of qemu used a default of "off", while newer qemus
have a default of "on"). <span class="since">Since
0.9.7</span>
</dd><dt><code>address</code></dt><dd>The <code>address</code> element for USB devices has a
<code>bus</code> and <code>device</code> attribute to specify the
USB bus and device number the device appears at on the host.
The values of these attributes can be given in decimal, hexadecimal
(starting with 0x) or octal (starting with 0) form.
For PCI devices the element carries 3 attributes allowing to designate
the device as can be found with the <code>lspci</code> or
with <code>virsh nodedev-list</code>. The
<code>bus</code> attribute allows the hexadecimal values 0 to ff, the
<code>slot</code> attribute allows the hexadecimal values 0 to 1f, and
the <code>function</code> attribute allows the hexadecimal values 0 to 7.
The <code>multifunction</code> attribute controls turning on the
multifunction bit for a particular slot/function in the PCI
control register<span class="since">since 0.9.7, requires QEMU
0.13</span>. <code>multifunction</code> defaults to 'off', but
should be set to 'on' for function 0 of a slot that will have
multiple functions used.
There is also an optional <code>domain</code> attribute for
the PCI domain, with hexadecimal values 0 to ffff, but it is
currently not used by qemu.</dd></dl>
<h4>
<a name="elementsRedir" id="elementsRedir">Redirected devices</a>
</h4>
<p>
USB device redirection through a character device is
supported <span class="since">since after 0.9.5 (KVM
only)</span>:
</p>
<pre>
...
<devices>
<redirdev bus='usb' type='tcp'>
<source mode='connect' host='localhost' service='4000'/>
</redirdev>
</devices>
...</pre>
<dl><dt><code>redirdev</code></dt><dd>The <code>redirdev</code> element is the main container for
describing redirected devices. <code>bus</code> must be "usb"
for a USB device.
An additional attribute <code>type</code> is required,
matching one of the
supported <a href="#elementsConsole">serial device</a> types,
to describe the host side of the
tunnel; <code>type='tcp'</code>
or <code>type='spicevmc'</code> (which uses the usbredir
channel of a <a href="#elementsGraphics">SPICE graphics
device</a>) are typical.</dd></dl>
<p>
The redirdev element has an optional sub-element
<code><address></code> which can tie the device to a
particular controller.
</p>
<p>
Further sub-elements, such as <code><source></code>, may
be required according to the given type, although
a <code><target></code> sub-element is not required (since
the consumer of the character device is the hypervisor itself,
rather than a device visible in the guest).
</p>
<h4>
<a name="elementsSmartcard" id="elementsSmartcard">Smartcard devices</a>
</h4>
<p>
A virtual smartcard device can be supplied to the guest via the
<code>smartcard</code> element. A USB smartcard reader device on
the host cannot be used on a guest with simple device
passthrough, since it will then not be available on the host,
possibly locking the host computer when it is "removed".
Therefore, some hypervisors provide a specialized virtual device
that can present a smartcard interface to the guest, with
several modes for describing how credentials are obtained from
the host or even a from a channel created to a third-party
smartcard provider. <span class="since">Since 0.8.8</span>
</p>
<pre>
...
<devices>
<smartcard mode='host'/>
<smartcard mode='host-certificates'>
<certificate>cert1</certificate>
<certificate>cert2</certificate>
<certificate>cert3</certificate>
<database>/etc/pki/nssdb/</database>
</smartcard>
<smartcard mode='passthrough' type='tcp'>
<source mode='bind' host='127.0.0.1' service='2001'/>
<protocol type='raw'/>
<address type='ccid' controller='0' slot='0'/>
</smartcard>
<smartcard mode='passthrough' type='spicevmc'/>
</devices>
...
</pre>
<p>
The <code><smartcard></code> element has a mandatory
attribute <code>mode</code>. The following modes are supported;
in each mode, the guest sees a device on its USB bus that
behaves like a physical USB CCID (Chip/Smart Card Interface
Device) card.
</p>
<dl><dt><code>mode='host'</code></dt><dd>The simplest operation, where the hypervisor relays all
requests from the guest into direct access to the host's
smartcard via NSS. No other attributes or sub-elements are
required. See below about the use of an
optional <code><address></code> sub-element.</dd><dt><code>mode='host-certificates'</code></dt><dd>Rather than requiring a smartcard to be plugged into the
host, it is possible to provide three NSS certificate names
residing in a database on the host. These certificates can be
generated via the command <code>certutil -d /etc/pki/nssdb -x -t
CT,CT,CT -S -s CN=cert1 -n cert1</code>, and the resulting three
certificate names must be supplied as the content of each of
three <code><certificate></code> sub-elements. An
additional sub-element <code><database></code> can specify
the absolute path to an alternate directory (matching
the <code>-d</code> option of the <code>certutil</code> command
when creating the certificates); if not present, it defaults to
/etc/pki/nssdb.</dd><dt><code>mode='passthrough'</code></dt><dd>Rather than having the hypervisor directly communicate with
the host, it is possible to tunnel all requests through a
secondary character device to a third-party provider (which may
in turn be talking to a smartcard or using three certificate
files). In this mode of operation, an additional
attribute <code>type</code> is required, matching one of the
supported <a href="#elementsConsole">serial device</a> types, to
describe the host side of the tunnel; <code>type='tcp'</code>
or <code>type='spicevmc'</code> (which uses the smartcard
channel of a <a href="#elementsGraphics">SPICE graphics
device</a>) are typical. Further sub-elements, such
as <code><source></code>, may be required according to the
given type, although a <code><target></code> sub-element
is not required (since the consumer of the character device is
the hypervisor itself, rather than a device visible in the
guest).</dd></dl>
<p>
Each mode supports an optional
sub-element <code><address></code>, which fine-tunes the
correlation between the smartcard and a ccid bus controller.
If present, the element must have an attribute
of <code>type='ccid'</code> as well as a <code>bus</code>
attribute listing the index of the bus that the smartcard
utilizes. An optional <code>slot</code> attribute lists which
slot within the bus. For now, qemu only supports at most one
smartcard, with an address of bus=0 slot=0.
</p>
<h4>
<a name="elementsNICS" id="elementsNICS">Network interfaces</a>
</h4>
<pre>
...
<devices>
<interface type='bridge'>
<source bridge='xenbr0'/>
<mac address='00:16:3e:5d:c7:9e'/>
<script path='vif-bridge'/>
<boot order='1'/>
</interface>
</devices>
...</pre>
<p>
There are several possibilities for specifying a network
interface visible to the guest. Each subsection below provides
more details about common setup options. Additionally,
each <code><interface></code> element has an
optional <code><address></code> sub-element that can tie
the interface to a particular pci slot, with
attribute <code>type='pci'</code> and additional
attributes <code>domain</code>, <code>bus</code>, <code>slot</code>,
<code>function</code>, and <code>multifunction</code>
<span class="since">since 0.9.7, requires QEMU 0.13</span> as appropriate.
</p>
<h5>
<a name="elementsNICSVirtual" id="elementsNICSVirtual">Virtual network</a>
</h5>
<p>
<strong><em>
This is the recommended config for general guest connectivity on
hosts with dynamic / wireless networking configs (or multi-host
environments where the host hardware details are described
separately in a <code><network></code>
definition <span class="since">Since 0.9.4</span>).
</em></strong>
</p>
<p>
Provides a connection whose details are described by the named
network definition. Depending on the virtual network's "forward
mode" configuration, the network may be totally isolated
(no <code><forward></code> element given), NAT'ing to an
explicit network device or to the default route
(<code><forward mode='nat'></code>), routed with no NAT
(<code><forward mode='route'/></code>), or connected
directly to one of the host's network interfaces (via macvtap)
or bridge devices ((<code><forward
mode='bridge|private|vepa|passthrough'/></code> <span class="since">Since
0.9.4</span>)
</p>
<p>
For networks with a forward mode of bridge, private, vepa, and
passthrough, it is assumed that the host has any necessary DNS
and DHCP services already setup outside the scope of libvirt. In
the case of isolated, nat, and routed networks, DHCP and DNS are
provided on the virtual network by libvirt, and the IP range can
be determined by examining the virtual network config with
'<code>virsh net-dumpxml [networkname]</code>'. There is one
virtual network called 'default' setup out of the box which does
NAT'ing to the default route and has an IP range
of <code>192.168.122.0/255.255.255.0</code>. Each guest will
have an associated tun device created with a name of vnetN,
which can also be overridden with the <target> element
(see
<a href="#elementsNICSTargetOverride">overriding the target element</a>).
</p>
<p>
When the source of an interface is a network,
a <code>portgroup</code> can be specified along with the name of
the network; one network may have multiple portgroups defined,
with each portgroup containing slightly different configuration
information for different classes of network
connections. <span class="since">Since 0.9.4</span>). Also,
similar to <code>direct</code> network connections (described
below), a connection of type <code>network</code> may specify
a <code>virtportprofile</code> element, with configuration data
to be forwarded to a vepa or 802.1Qbh compliant switch.
</p>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
</interface>
...
<interface type='network'>
<source network='default' portgroup='engineering'/>
<target dev='vnet7'/>
<mac address="00:11:22:33:44:55"/>
<virtualport type='802.1Qbg'>
<parameters managerid='11' typeid='1193047' typeidversion='2' instanceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/>
</virtualport>
</interface>
</devices>
...</pre>
<h5>
<a name="elementsNICSBridge" id="elementsNICSBridge">Bridge to LAN</a>
</h5>
<p>
<strong><em>
This is the recommended config for general guest connectivity on
hosts with static wired networking configs
</em></strong>
</p>
<p>
Provides a bridge from the VM directly onto the LAN. This assumes
there is a bridge device on the host which has one or more of the hosts
physical NICs enslaved. The guest VM will have an associated tun device
created with a name of vnetN, which can also be overridden with the
<target> element (see
<a href="#elementsNICSTargetOverride">overriding the target element</a>).
The tun device will be enslaved to the bridge. The IP range / network
configuration is whatever is used on the LAN. This provides the guest VM
full incoming & outgoing net access just like a physical machine.
</p>
<pre>
...
<devices>
<interface type='bridge'>
<source bridge='br0'/>
</interface>
...
<interface type='bridge'>
<source bridge='br0'/>
<target dev='vnet7'/>
<mac address="00:11:22:33:44:55"/>
</interface>
</devices>
...</pre>
<h5>
<a name="elementsNICSSlirp" id="elementsNICSSlirp">Userspace SLIRP stack</a>
</h5>
<p>
Provides a virtual LAN with NAT to the outside world. The virtual
network has DHCP & DNS services and will give the guest VM addresses
starting from <code>10.0.2.15</code>. The default router will be
<code>10.0.2.2</code> and the DNS server will be <code>10.0.2.3</code>.
This networking is the only option for unprivileged users who need their
VMs to have outgoing access.
</p>
<pre>
...
<devices>
<interface type='user'/>
...
<interface type='user'>
<mac address="00:11:22:33:44:55"/>
</interface>
</devices>
...</pre>
<h5>
<a name="elementsNICSEthernet" id="elementsNICSEthernet">Generic ethernet connection</a>
</h5>
<p>
Provides a means for the administrator to execute an arbitrary script
to connect the guest's network to the LAN. The guest will have a tun
device created with a name of vnetN, which can also be overridden with the
<target> element. After creating the tun device a shell script will
be run which is expected to do whatever host network integration is
required. By default this script is called /etc/qemu-ifup but can be
overridden.
</p>
<pre>
...
<devices>
<interface type='ethernet'/>
...
<interface type='ethernet'>
<target dev='vnet7'/>
<script path='/etc/qemu-ifup-mynet'/>
</interface>
</devices>
...</pre>
<h5>
<a name="elementsNICSDirect" id="elementsNICSDirect">Direct attachment to physical interface</a>
</h5>
<p>
Provides direct attachment of the virtual machine's NIC to the given
physial interface of the host.
<span class="since">Since 0.7.7 (QEMU and KVM only)</span><br />
This setup requires the Linux macvtap
driver to be available. <span class="since">(Since Linux 2.6.34.)</span>
One of the modes 'vepa'
( <a href="http://www.ieee802.org/1/files/public/docs2009/new-evb-congdon-vepa-modular-0709-v01.pdf">
'Virtual Ethernet Port Aggregator'</a>), 'bridge' or 'private'
can be chosen for the operation mode of the macvtap device, 'vepa'
being the default mode. The individual modes cause the delivery of
packets to behave as follows:
</p>
<dl><dt><code>vepa</code></dt><dd>All VMs' packets are sent to the external bridge. Packets
whose destination is a VM on the same host as where the
packet originates from are sent back to the host by the VEPA
capable bridge (today's bridges are typically not VEPA capable).</dd><dt><code>bridge</code></dt><dd>Packets whose destination is on the same host as where they
originate from are directly delivered to the target macvtap device.
Both origin and destination devices need to be in bridge mode
for direct delivery. If either one of them is in <code>vepa</code> mode,
a VEPA capable bridge is required.</dd><dt><code>private</code></dt><dd>All packets are sent to the external bridge and will only be
delivered to a target VM on the same host if they are sent through an
external router or gateway and that device sends them back to the
host. This procedure is followed if either the source or destination
device is in <code>private</code> mode.</dd><dt><code>passthrough</code></dt><dd>This feature attaches a virtual function of a SRIOV capable
NIC directly to a VM without losing the migration capability.
All packets are sent to the VF/IF of the configured network device.
Depending on the capabilities of the device additional prerequisites or
limitations may apply; for example, on Linux this requires
kernel 2.6.38 or newer. <span class="since">Since 0.9.2</span></dd></dl>
<pre>
...
<devices>
<interface type='direct'/>
...
<interface type='direct'>
<source dev='eth0' mode='vepa'/>
</interface>
</devices>
...</pre>
<p>
The network access of direct attached virtual machines can be
managed by the hardware switch to which the physical interface
of the host machine is connected to.
</p>
<p>
The interface can have additional parameters as shown below,
if the switch is conforming to the IEEE 802.1Qbg standard.
The parameters of the virtualport element are documented in more detail
in the IEEE 802.1Qbg standard. The values are network specific and
should be provided by the network administrator. In 802.1Qbg terms,
the Virtual Station Interface (VSI) represents the virtual interface
of a virtual machine. <span class="since">Since 0.8.2</span>
</p>
<p>
Please note that IEEE 802.1Qbg requires a non-zero value for the
VLAN ID.
</p>
<dl><dt><code>managerid</code></dt><dd>The VSI Manager ID identifies the database containing the VSI type
and instance definitions. This is an integer value and the
value 0 is reserved.</dd><dt><code>typeid</code></dt><dd>The VSI Type ID identifies a VSI type characterizing the network
access. VSI types are typically managed by network administrator.
This is an integer value.
</dd><dt><code>typeidversion</code></dt><dd>The VSI Type Version allows multiple versions of a VSI Type.
This is an integer value.
</dd><dt><code>instanceid</code></dt><dd>The VSI Instance ID Identifier is generated when a VSI instance
(i.e. a virtual interface of a virtual machine) is created.
This is a globally unique identifier.
</dd></dl>
<pre>
...
<devices>
<interface type='direct'/>
...
<interface type='direct'>
<source dev='eth0.2' mode='vepa'/>
<virtualport type="802.1Qbg">
<parameters managerid="11" typeid="1193047" typeidversion="2" instanceid="09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f"/>
</virtualport>
</interface>
</devices>
...</pre>
<p>
The interface can have additional parameters as shown below
if the switch is conforming to the IEEE 802.1Qbh standard.
The values are network specific and should be provided by the
network administrator. <span class="since">Since 0.8.2</span>
</p>
<dl><dt><code>profileid</code></dt><dd>The profile ID contains the name of the port profile that is to
be applied onto this interface. This name is resolved by the port
profile database into the network parameters from the port profile,
and those network parameters will be applied to this interface.
</dd></dl>
<pre>
...
<devices>
<interface type='direct'/>
...
<interface type='direct'>
<source dev='eth0' mode='private'/>
<virtualport type='802.1Qbh'>
<parameters profileid='finance'/>
</virtualport>
</interface>
</devices>
...
</pre>
<h5>
<a name="elementsNICSMulticast" id="elementsNICSMulticast">Multicast tunnel</a>
</h5>
<p>
A multicast group is setup to represent a virtual network. Any VMs
whose network devices are in the same multicast group can talk to each
other even across hosts. This mode is also available to unprivileged
users. There is no default DNS or DHCP support and no outgoing network
access. To provide outgoing network access, one of the VMs should have a
2nd NIC which is connected to one of the first 4 network types and do the
appropriate routing. The multicast protocol is compatible with that used
by user mode linux guests too. The source address used must be from the
multicast address block.
</p>
<pre>
...
<devices>
<interface type='mcast'>
<source address='230.0.0.1' port='5558'/>
</interface>
</devices>
...</pre>
<h5>
<a name="elementsNICSTCP" id="elementsNICSTCP">TCP tunnel</a>
</h5>
<p>
A TCP client/server architecture provides a virtual network. One VM
provides the server end of the network, all other VMS are configured as
clients. All network traffic is routed between the VMs via the server.
This mode is also available to unprivileged users. There is no default
DNS or DHCP support and no outgoing network access. To provide outgoing
network access, one of the VMs should have a 2nd NIC which is connected
to one of the first 4 network types and do the appropriate routing.</p>
<pre>
...
<devices>
<interface type='server'>
<source address='192.168.0.1' port='5558'/>
</interface>
...
<interface type='client'>
<source address='192.168.0.1' port='5558'/>
</interface>
</devices>
...</pre>
<h5>
<a name="elementsNICSModel" id="elementsNICSModel">Setting the NIC model</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet1'/>
<b><model type='ne2k_pci'/></b>
</interface>
</devices>
...</pre>
<p>
For hypervisors which support this, you can set the model of
emulated network interface card.
</p>
<p>
The values for <code>type</code> aren't defined specifically by
libvirt, but by what the underlying hypervisor supports (if
any). For QEMU and KVM you can get a list of supported models
with these commands:
</p>
<pre>
qemu -net nic,model=? /dev/null
qemu-kvm -net nic,model=? /dev/null
</pre>
<p>
Typical values for QEMU and KVM include:
ne2k_isa i82551 i82557b i82559er ne2k_pci pcnet rtl8139 e1000 virtio
</p>
<h5>
<a name="elementsDriverBackendOptions" id="elementsDriverBackendOptions">Setting NIC driver-specific options</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet1'/>
<model type='virtio'/>
<b><driver name='vhost' txmode='iothread' ioeventfd='on' event_idx='off'/></b>
</interface>
</devices>
...</pre>
<p>
Some NICs may have tunable driver-specific options. These are
set as attributes of the <code>driver</code> sub-element of the
interface definition. Currently the following attributes are
available for the <code>"virtio"</code> NIC driver:
</p>
<dl><dt><code>name</code></dt><dd>
The optional <code>name</code> attribute forces which type of
backend driver to use. The value can be either 'qemu' (a
user-space backend) or 'vhost' (a kernel backend, which
requires the vhost module to be provided by the kernel); an
attempt to require the vhost driver without kernel support
will be rejected. If this attribute is not present, then the
domain defaults to 'vhost' if present, but silently falls back
to 'qemu' without error.
<span class="since">Since 0.8.8 (QEMU and KVM only)</span>
</dd><dt><code>txmode</code></dt><dd>
The <code>txmode</code> attribute specifies how to handle
transmission of packets when the transmit buffer is full. The
value can be either 'iothread' or 'timer'.
<span class="since">Since 0.8.8 (QEMU and KVM only)</span><br /><br />
If set to 'iothread', packet tx is all done in an iothread in
the bottom half of the driver (this option translates into
adding "tx=bh" to the qemu commandline -device virtio-net-pci
option).<br /><br />
If set to 'timer', tx work is done in qemu, and if there is
more tx data than can be sent at the present time, a timer is
set before qemu moves on to do other things; when the timer
fires, another attempt is made to send more data.<br /><br />
The resulting difference, according to the qemu developer who
added the option is: "bh makes tx more asynchronous and reduces
latency, but potentially causes more processor bandwidth
contention since the cpu doing the tx isn't necessarily the
cpu where the guest generated the packets."<br /><br /><b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</dd><dt><code>ioeventfd</code></dt><dd>
This optional attribute allows users to set
<a href="https://patchwork.kernel.org/patch/43390/">
domain I/O asynchronous handling</a> for interface device.
The default is left to the discretion of the hypervisor.
Accepted values are "on" and "off". Enabling this allows
qemu to execute VM while a separate thread handles I/O.
Typically guests experiencing high system CPU utilization
during I/O will benefit from this. On the other hand,
on overloaded host it could increase guest I/O latency.
<span class="since">Since 0.9.3 (QEMU and KVM only)</span><br /><br /><b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</dd><dt><code>event_idx</code></dt><dd>
The <code>event_idx</code> attribute controls some aspects of
device event processing. The value can be either 'on' or 'off'
- if it is on, it will reduce the number of interupts and
exits for the guest. The default is determined by QEMU;
usually if the feature is supported, default is on. In case
there is a situation where this behavior is suboptimal, this
attribute provides a way to force the feature off.
<span class="since">Since 0.9.5 (QEMU and KVM only)</span><br /><br /><b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</dd></dl>
<h5>
<a name="elementsNICSTargetOverride" id="elementsNICSTargetOverride">Overriding the target element</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<b><target dev='vnet1'/></b>
</interface>
</devices>
...</pre>
<p>
If no target is specified, certain hypervisors will
automatically generate a name for the created tun device. This
name can be manually specifed, however the name <i>must not
start with either 'vnet' or 'vif'</i>, which are prefixes
reserved by libvirt and certain hypervisors. Manually specified
targets using these prefixes will be ignored.
</p>
<h5>
<a name="elementsNICSBoot" id="elementsNICSBoot">Specifying boot order</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet1'/>
<b><boot order='1'/></b>
</interface>
</devices>
...</pre>
<p>
For hypervisors which support this, you can set exact NIC which should
be used for network boot. The <code>order</code> attribute determines
the order in which devices will be tried during boot sequence. The
per-device <code>boot</code> elements cannot be used together with
general boot elements in
<a href="#elementsOSBIOS">BIOS bootloader</a> section.
<span class="since">Since 0.8.8</span>
</p>
<h5>
<a name="elementQoS" id="elementQoS">Quality of service</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet0'/>
<b><bandwidth>
<inbound average='1000' peak='5000' burst='1024'/>
<outbound average='128' peak='256' burst='256'/>
</bandwidth></b>
</interface>
<devices>
...</pre>
<p>
This part of interface XML provides setting quality of service. Incoming
and outgoing traffic can be shaped independently. The
<code>bandwidth</code> element can have at most one <code>inbound</code>
and at most one <code>outbound</code> child elements. Leaving any of these
children element out result in no QoS applied on that traffic direction.
So, when you want to shape only domain's incoming traffic, use
<code>inbound</code> only, and vice versa. Each of these elements have one
mandatory attribute <code>average</code>. It specifies average bit rate on
interface being shaped. Then there are two optional attributes:
<code>peak</code>, which specifies maximum rate at which interface can send
data, and <code>burst</code>, amount of bytes that can be burst at
<code>peak</code> speed. Accepted values for attributes are integer
numbers. The units for <code>average</code> and <code>peak</code> attributes
are kilobytes per second, and for the <code>burst</code> just kilobytes.
<span class="since">Since 0.9.4</span>
</p>
<h5>
<a name="elementLink" id="elementLink">Modyfing virtual link state</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet0'/>
<b><link state='down'/></b>
</interface>
<devices>
...</pre>
<p>
This element provides means of setting state of the virtual network link.
Possible values for attribute <code>state</code> are <code>up</code> and
<code>down</code>. If <code>down</code> is specified as the value, the interface
behaves as if it had the network cable disconnected. Default behavior if this
element is unspecified is to have the link state <code>up</code>.
<span class="since">Since 0.9.5</span>
</p>
<h4>
<a name="elementsInput" id="elementsInput">Input devices</a>
</h4>
<p>
Input devices allow interaction with the graphical framebuffer
in the guest virtual machine. When enabling the framebuffer, an
input device is automatically provided. It may be possible to
add additional devices explicitly, for example,
to provide a graphics tablet for absolute cursor movement.
</p>
<pre>
...
<devices>
<input type='mouse' bus='usb'/>
</devices>
...</pre>
<dl><dt><code>input</code></dt><dd>The <code>input</code> element has one mandatory attribute,
the <code>type</code> whose value can be either 'mouse' or
'tablet'. The latter provides absolute
cursor movement, while the former uses relative movement. The optional
<code>bus</code> attribute can be used to refine the exact device type.
It takes values "xen" (paravirtualized), "ps2" and "usb".</dd></dl>
<p>
The <code>input</code> element has an optional
sub-element <code><address></code> which can tie the
device to a particular PCI slot.
</p>
<h4>
<a name="elementsHub" id="elementsHub">Hub devices</a>
</h4>
<p>
A hub is a device that expands a single port into several so
that there are more ports available to connect devices to a host
system.
</p>
<pre>
...
<devices>
<hub type='usb'/>
</devices>
...</pre>
<dl><dt><code>hub</code></dt><dd>The <code>hub</code> element has one mandatory attribute,
the <code>type</code> whose value can only be 'usb'.</dd></dl>
<p>
The <code>hub</code> element has an optional
sub-element <code><address></code> which can tie the
device to a particular controller.
</p>
<h4>
<a name="elementsGraphics" id="elementsGraphics">Graphical framebuffers</a>
</h4>
<p>
A graphics device allows for graphical interaction with the
guest OS. A guest will typically have either a framebuffer
or a text console configured to allow interaction with the
admin.
</p>
<pre>
...
<devices>
<graphics type='sdl' display=':0.0'/>
<graphics type='vnc' port='5904'>
<listen type='address' address='1.2.3.4'/>
</graphics>
<graphics type='rdp' autoport='yes' multiUser='yes' />
<graphics type='desktop' fullscreen='yes'/>
<graphics type='spice'>
<listen type='network' network='rednet'/>
</graphics>
</devices>
...</pre>
<dl><dt><code>graphics</code></dt><dd>The <code>graphics</code> element has a mandatory <code>type</code>
attribute which takes the value "sdl", "vnc", "rdp" or "desktop":
<dl><dt><code>"sdl"</code></dt><dd>
This displays a window on the host desktop, it can take 3
optional arguments: a <code>display</code> attribute for
the display to use, an <code>xauth</code> attribute for
the authentication identifier, and an
optional <code>fullscreen</code> attribute accepting
values 'yes' or 'no'.
</dd><dt><code>"vnc"</code></dt><dd>
Starts a VNC server. The <code>port</code> attribute
specifies the TCP port number (with -1 as legacy syntax
indicating that it should be
auto-allocated). The <code>autoport</code> attribute is
the new preferred syntax for indicating autoallocation of
the TCP port to use. The <code>listen</code> attribute is
an IP address for the server to listen
on. The <code>passwd</code> attribute provides a VNC
password in clear text. The <code>keymap</code> attribute
specifies the keymap to use. It is possible to set a limit
on the validity of the password be giving an
timestamp <code>passwdValidTo='2010-04-09T15:51:00'</code>
assumed to be in UTC. The <code>connected</code> attribute
allows control of connected client during password changes.
VNC accepts <code>keep</code> value only.
<span class="since">since 0.9.3</span>
NB, this may not be supported by all hypervisors.<br /><br />
Rather than using listen/port, QEMU supports a
<code>socket</code> attribute for listening on a unix
domain socket path.<span class="since">Since 0.8.8</span>
</dd><dt><code>"spice"</code></dt><dd>
<p>
Starts a SPICE server. The <code>port</code> attribute
specifies the TCP port number (with -1 as legacy syntax
indicating that it should be auto-allocated),
while <code>tlsPort</code> gives an alternative secure
port number. The <code>autoport</code> attribute is the
new preferred syntax for indicating autoallocation of
both port numbers. The <code>listen</code> attribute is
an IP address for the server to listen
on. The <code>passwd</code> attribute provides a SPICE
password in clear text. The <code>keymap</code>
attribute specifies the keymap to use. It is possible to
set a limit on the validity of the password be giving an
timestamp <code>passwdValidTo='2010-04-09T15:51:00'</code>
assumed to be in UTC. The <code>connected</code> attribute
allows control of connected client during password changes.
SPICE accepts <code>keep</code> to keep client connected,
<code>disconnect</code> to disconnect client and
<code>fail</code> to fail changing password.
<span class="since">Since 0.9.3</span>
NB, this may not be supported by all hypervisors.
<span class="since">"spice" since 0.8.6</span>.
</p>
<p>
When SPICE has both a normal and TLS secured TCP port
configured, it can be desirable to restrict what
channels can be run on each port. This is achieved by
adding one or more <channel> elements inside the
main <graphics> element. Valid channel names
include <code>main</code>, <code>display</code>,
<code>inputs</code>, <code>cursor</code>,
<code>playback</code>, <code>record</code>;
and <span class="since">since
0.8.8</span>: <code>smartcard</code>.
</p>
<pre>
<graphics type='spice' port='-1' tlsPort='-1' autoport='yes'>
<channel name='main' mode='secure'/>
<channel name='record' mode='insecure'/>
<image compression='auto_glz'/>
<streaming mode='filter'/>
<clipboard copypaste='no'/>
</graphics></pre>
<p>
Spice supports variable compression settings for audio,
images and streaming, <span class="since">since
0.9.1</span>. These settings are accessible via
the <code>compression</code> attribute in all following
elements: <code>image</code> to set image compression
(accepts <code>auto_glz</code>, <code>auto_lz</code>,
<code>quic</code>, <code>glz</code>, <code>lz</code>,
<code>off</code>), <code>jpeg</code> for JPEG
compression for images over wan
(accepts <code>auto</code>, <code>never</code>,
<code>always</code>), <code>zlib</code> for configuring
wan image compression (accepts <code>auto</code>,
<code>never</code>, <code>always</code>)
and <code>playback</code> for enabling audio stream
compression (accepts <code>on</code> or <code>off</code>).
</p>
<p>
Streaming mode is set by the <code>streaming</code>
element, settings it's <code>mode</code> attribute to one
of <code>filter</code>, <code>all</code>
or <code>off</code>, <span class="since">since 0.9.2</span>.
</p>
<p>
Copy & Paste functionality (via Spice agent) is set
by the <code>clipboard</code> element. It is enabled by
default, and can be disabled by setting
the <code>copypaste</code> property
to <code>no</code>, <span class="since">since
0.9.3</span>.
</p>
</dd><dt><code>"rdp"</code></dt><dd>
Starts a RDP server. The <code>port</code> attribute
specifies the TCP port number (with -1 as legacy syntax
indicating that it should be
auto-allocated). The <code>autoport</code> attribute is
the new preferred syntax for indicating autoallocation of
the TCP port to use. The <code>replaceUser</code>
attribute is a boolean deciding whether multiple
simultaneous connections to the VM are permitted.
The <code>multiUser</code> whether the existing connection
must be dropped and a new connection must be established
by the VRDP server, when a new client connects in single
connection mode.
</dd><dt><code>"desktop"</code></dt><dd>
This value is reserved for VirtualBox domains for the
moment. It displays a window on the host desktop,
similarly to "sdl", but using the VirtualBox viewer. Just
like "sdl", it accepts the optional
attributes <code>display</code>
and <code>fullscreen</code>.
</dd></dl></dd></dl>
<p>
Rather than putting the address information used to set up the
listening socket for graphics types <code>vnc</code>
and <code>spice</code> in
the <code><graphics></code> <code>listen</code> attribute,
a separate subelement of <code><graphics></code>,
called <code><listen></code> can be specified (see the
examples above)<span class="since">since
0.9.4</span>. <code><listen></code> accepts the following
attributes:
</p>
<dl><dt><code>type</code></dt><dd>Set to either <code>address</code>
or <code>network</code>. This tells whether this listen
element is specifying the address to be used directly, or by
naming a network (which will then be used to determine an
appropriate address for listening).
</dd></dl>
<dl><dt><code>address</code></dt><dd>if <code>type='address'</code>, the <code>address</code>
attribute will contain either an IP address or hostname (which
will be resolved to an IP address via a DNS query) to listen
on. In the "live" XML of a running domain, this attribute will
be set to the IP address used for listening, even
if <code>type='network'</code>.
</dd></dl>
<dl><dt><code>network</code></dt><dd>if <code>type='network'</code>, the <code>network</code>
attribute will contain the name of a network in libvirt's list
of configured networks. The named network configuration will
be examined to determine an appropriate listen address. For
example, if the network has an IPv4 address in its
configuration (e.g. if it has a forward type
of <code>route</code>, <code>nat</code>, or no forward type
(isolated)), the first IPv4 address listed in the network's
configuration will be used. If the network is describing a
host bridge, the first IPv4 address associated with that
bridge device will be used, and if the network is describing
one of the 'direct' (macvtap) modes, the first IPv4 address of
the first forward dev will be used.
</dd></dl>
<h4>
<a name="elementsVideo" id="elementsVideo">Video devices</a>
</h4>
<p>
A video device.
</p>
<pre>
...
<devices>
<video>
<model type='vga' vram='8192' heads='1'>
<acceleration accel3d='yes' accel3d='yes'/>
</model>
</video>
</devices>
...</pre>
<dl><dt><code>video</code></dt><dd>
The <code>video</code> element is the a container for describing
video devices. For backwards compatability, if no <code>video</code>
is set but there is a <code>graphics</code> in domain xml, then libvirt
will add a default <code>video</code> according to the guest type.
For a guest of type "kvm", the default <code>video</code> for it is:
<code>type</code> with value "cirrus", <code>vram</code> with value
"9216", and <code>heads</code> with value "1".
</dd><dt><code>model</code></dt><dd>
The <code>model</code> element has a mandatory <code>type</code>
attribute which takes the value "vga", "cirrus", "vmvga", "xen",
"vbox", or "qxl" (<span class="since">since 0.8.6</span>)
depending on the hypervisor features available.
You can also provide the amount of video memory in kilobytes using
<code>vram</code> and the number of screen with <code>heads</code>.
</dd><dt><code>acceleration</code></dt><dd>
If acceleration should be enabled (if supported) using the
<code>accel3d</code> and <code>accel2d</code> attributes in the
<code>acceleration</code> element.
</dd><dt><code>address</code></dt><dd>
The optional <code>address</code> sub-element can be used to
tie the video device to a particular PCI slot.
</dd></dl>
<h4>
<a name="elementsConsole" id="elementsConsole">Consoles, serial, parallel & channel devices</a>
</h4>
<p>
A character device provides a way to interact with the virtual machine.
Paravirtualized consoles, serial ports, parallel ports and channels are
all classed as character devices and so represented using the same syntax.
</p>
<pre>
...
<devices>
<parallel type='pty'>
<source path='/dev/pts/2'/>
<target port='0'/>
</parallel>
<serial type='pty'>
<source path='/dev/pts/3'/>
<target port='0'/>
</serial>
<console type='pty'>
<source path='/dev/pts/4'/>
<target port='0'/>
</console>
<channel type='unix'>
<source mode='bind' path='/tmp/guestfwd'/>
<target type='guestfwd' address='10.0.2.1' port='4600'/>
</channel>
</devices>
...</pre>
<p>
In each of these directives, the top-level element name (parallel, serial,
console, channel) describes how the device is presented to the guest. The
guest interface is configured by the <code>target</code> element.
</p>
<p>
The interface presented to the host is given in the <code>type</code>
attribute of the top-level element. The host interface is
configured by the <code>source</code> element.
</p>
<p>
Each character device element has an optional
sub-element <code><address></code> which can tie the
device to a
particular <a href="#elementsControllers">controller</a> or PCI
slot.
</p>
<h5>
<a name="elementsCharGuestInterface" id="elementsCharGuestInterface">Guest interface</a>
</h5>
<p>
A character device presents itself to the guest as one of the following
types.
</p>
<h6>
<a name="elementCharParallel" id="elementCharParallel">Parallel port</a>
</h6>
<pre>
...
<devices>
<parallel type='pty'>
<source path='/dev/pts/2'/>
<target port='0'/>
</parallel>
</devices>
...</pre>
<p>
<code>target</code> can have a <code>port</code> attribute, which
specifies the port number. Ports are numbered starting from 0. There are
usually 0, 1 or 2 parallel ports.
</p>
<h6>
<a name="elementCharSerial" id="elementCharSerial">Serial port</a>
</h6>
<pre>
...
<devices>
<serial type='pty'>
<source path='/dev/pts/3'/>
<target port='0'/>
</serial>
</devices>
...</pre>
<p>
<code>target</code> can have a <code>port</code> attribute, which
specifies the port number. Ports are numbered starting from 0. There are
usually 0, 1 or 2 serial ports.
</p>
<h6>
<a name="elementCharConsole" id="elementCharConsole">Console</a>
</h6>
<p>
The console element is used to represent interactive consoles. Depending
on the type of guest in use, the consoles might be paravirtualized devices,
or they might be a clone of a serial device, according to the following
rules:
</p>
<ul><li>If no <code>targetType</code> attribue is set, then the default
device type is according to the hypervisor's rules. The default
type will be added when re-querying the XML fed into libvirt.
For fully virtualized guests, the default device type will usually
be a serial port.</li><li>If the <code>targetType</code> attribute is <code>serial</code>,
then if no <code><serial></code> element exists, the console
element will be copied to the serial element. If a <code><serial></code>
element does already exist, the console element will be ignored.</li><li>If the <code>targetType</code> attribute is not <code>serial</code>,
it will be treated normally.</li><li>Only the first <code>console</code> element may use a <code>targetType</code>
of <code>serial</code>. Secondary consoles must all be paravirtualized.
</li></ul>
<p>
A virtio console device is exposed in the
guest as /dev/hvc[0-7] (for more information, see
<a href="http://fedoraproject.org/wiki/Features/VirtioSerial">http://fedoraproject.org/wiki/Features/VirtioSerial</a>)
<span class="since">Since 0.8.3</span>
</p>
<pre>
...
<devices>
<console type='pty'>
<source path='/dev/pts/4'/>
<target port='0'/>
</console>
<!-- KVM virtio console -->
<console type='pty'>
<source path='/dev/pts/5'/>
<target type='virtio' port='0'/>
</console>
</devices>
...</pre>
<p>
If the console is presented as a serial port, the <code>target</code>
element has the same attributes as for a serial port. There is usually
only 1 console.
</p>
<h6>
<a name="elementCharChannel" id="elementCharChannel">Channel</a>
</h6>
<p>
This represents a private communication channel between the host and the
guest.
</p>
<pre>
...
<devices>
<channel type='unix'>
<source mode='bind' path='/tmp/guestfwd'/>
<target type='guestfwd' address='10.0.2.1' port='4600'/>
</channel>
<!-- KVM virtio channel -->
<channel type='pty'>
<target type='virtio' name='arbitrary.virtio.serial.port.name'/>
</channel>
<channel type='spicevmc'>
<target type='virtio' name='com.redhat.spice.0'/>
</channel>
</devices>
...</pre>
<p>
This can be implemented in a variety of ways. The specific type of
channel is given in the <code>type</code> attribute of the
<code>target</code> element. Different channel types have different
<code>target</code> attributes.
</p>
<dl><dt><code>guestfwd</code></dt><dd>TCP traffic sent by the guest to a given IP address and port is
forwarded to the channel device on the host. The <code>target</code>
element must have <code>address</code> and <code>port</code> attributes.
<span class="since">Since 0.7.3</span></dd><dt><code>virtio</code></dt><dd>Paravirtualized virtio channel. Channel is exposed in the guest under
/dev/vport*, and if the optional element <code>name</code> is specified,
/dev/virtio-ports/$name (for more info, please see
<a href="http://fedoraproject.org/wiki/Features/VirtioSerial">http://fedoraproject.org/wiki/Features/VirtioSerial</a>). The
optional element <code>address</code> can tie the channel to a
particular <code>type='virtio-serial'</code> controller.
<span class="since">Since 0.7.7</span></dd><dt><code>spicevmc</code></dt><dd>Paravirtualized SPICE channel. The domain must also have a
SPICE server as a <a href="#elementsGraphics">graphics
device</a>, at which point the host piggy-backs messages
across the <code>main</code> channel. The <code>target</code>
element must be present, with
attribute <code>type='virtio'</code>; an optional
attribute <code>name</code> controls how the guest will have
access to the channel, and defaults
to <code>name='com.redhat.spice.0'</code>. The
optional <code>address</code> element can tie the channel to a
particular <code>type='virtio-serial'</code> controller.
<span class="since">Since 0.8.8</span></dd></dl>
<h5>
<a name="elementsCharHostInterface" id="elementsCharHostInterface">Host interface</a>
</h5>
<p>
A character device presents itself to the host as one of the following
types.
</p>
<h6>
<a name="elementsCharSTDIO" id="elementsCharSTDIO">Domain logfile</a>
</h6>
<p>
This disables all input on the character device, and sends output
into the virtual machine's logfile
</p>
<pre>
...
<devices>
<console type='stdio'>
<target port='1'>
</console>
</devices>
...</pre>
<h6>
<a name="elementsCharFle" id="elementsCharFle">Device logfile</a>
</h6>
<p>
A file is opened and all data sent to the character
device is written to the file.
</p>
<pre>
...
<devices>
<serial type="file">
<source path="/var/log/vm/vm-serial.log"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a name="elementsCharVC" id="elementsCharVC">Virtual console</a>
</h6>
<p>
Connects the character device to the graphical framebuffer in
a virtual console. This is typically accessed via a special
hotkey sequence such as "ctrl+alt+3"
</p>
<pre>
...
<devices>
<serial type='vc'>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a name="elementsCharNull" id="elementsCharNull">Null device</a>
</h6>
<p>
Connects the character device to the void. No data is ever
provided to the input. All data written is discarded.
</p>
<pre>
...
<devices>
<serial type='null'>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a name="elementsCharPTY" id="elementsCharPTY">Pseudo TTY</a>
</h6>
<p>
A Pseudo TTY is allocated using /dev/ptmx. A suitable client
such as 'virsh console' can connect to interact with the
serial port locally.
</p>
<pre>
...
<devices>
<serial type="pty">
<source path="/dev/pts/3"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<p>
NB special case if <console type='pty'>, then the TTY
path is also duplicated as an attribute tty='/dev/pts/3'
on the top level <console> tag. This provides compat
with existing syntax for <console> tags.
</p>
<h6>
<a name="elementsCharHost" id="elementsCharHost">Host device proxy</a>
</h6>
<p>
The character device is passed through to the underlying
physical character device. The device types must match,
eg the emulated serial port should only be connected to
a host serial port - don't connect a serial port to a parallel
port.
</p>
<pre>
...
<devices>
<serial type="dev">
<source path="/dev/ttyS0"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a name="elementsCharPipe" id="elementsCharPipe">Named pipe</a>
</h6>
<p>
The character device writes output to a named pipe. See pipe(7) for
more info.
</p>
<pre>
...
<devices>
<serial type="pipe">
<source path="/tmp/mypipe"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a name="elementsCharTCP" id="elementsCharTCP">TCP client/server</a>
</h6>
<p>
The character device acts as a TCP client connecting to a
remote server.
</p>
<pre>
...
<devices>
<serial type="tcp">
<source mode="connect" host="0.0.0.0" service="2445"/>
<protocol type="raw"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<p>
Or as a TCP server waiting for a client connection.
</p>
<pre>
...
<devices>
<serial type="tcp">
<source mode="bind" host="127.0.0.1" service="2445"/>
<protocol type="raw"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<p>
Alternatively you can use <code>telnet</code> instead
of <code>raw</code> TCP. <span class="since">Since 0.8.5</span>
you can also use <code>telnets</code>
(secure telnet) and <code>tls</code>.
</p>
<pre>
...
<devices>
<serial type="tcp">
<source mode="connect" host="0.0.0.0" service="2445"/>
<protocol type="telnet"/>
<target port="1"/>
</serial>
...
<serial type="tcp">
<source mode="bind" host="127.0.0.1" service="2445"/>
<protocol type="telnet"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a name="elementsCharUDP" id="elementsCharUDP">UDP network console</a>
</h6>
<p>
The character device acts as a UDP netconsole service,
sending and receiving packets. This is a lossy service.
</p>
<pre>
...
<devices>
<serial type="udp">
<source mode="bind" host="0.0.0.0" service="2445"/>
<source mode="connect" host="0.0.0.0" service="2445"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a name="elementsCharUNIX" id="elementsCharUNIX">UNIX domain socket client/server</a>
</h6>
<p>
The character device acts as a UNIX domain socket server,
accepting connections from local clients.
</p>
<pre>
...
<devices>
<serial type="unix">
<source mode="bind" path="/tmp/foo"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h4>
<a name="elementsSound" id="elementsSound">Sound devices</a>
</h4>
<p>
A virtual sound card can be attached to the host via the
<code>sound</code> element. <span class="since">Since 0.4.3</span>
</p>
<pre>
...
<devices>
<sound model='es1370'/>
</devices>
...</pre>
<dl><dt><code>sound</code></dt><dd>
The <code>sound</code> element has one mandatory attribute,
<code>model</code>, which specifies what real sound device is emulated.
Valid values are specific to the underlying hypervisor, though typical
choices are 'es1370', 'sb16', 'ac97', and 'ich6'
(<span class="since">
'ac97' only since 0.6.0, 'ich6' only since 0.8.8</span>)
</dd></dl>
<p>
Each <code>sound</code> element has an optional
sub-element <code><address></code> which can tie the
device to a particular PCI slot.
</p>
<h4>
<a name="elementsWatchdog" id="elementsWatchdog">Watchdog device</a>
</h4>
<p>
A virtual hardware watchdog device can be added to the guest via
the <code>watchdog</code> element.
<span class="since">Since 0.7.3, QEMU and KVM only</span>
</p>
<p>
The watchdog device requires an additional driver and management
daemon in the guest. Just enabling the watchdog in the libvirt
configuration does not do anything useful on its own.
</p>
<p>
Currently libvirt does not support notification when the
watchdog fires. This feature is planned for a future version of
libvirt.
</p>
<pre>
...
<devices>
<watchdog model='i6300esb'/>
</devices>
...</pre>
<pre>
...
<devices>
<watchdog model='i6300esb' action='poweroff'/>
</devices>
</domain></pre>
<dl><dt><code>model</code></dt><dd>
<p>
The required <code>model</code> attribute specifies what real
watchdog device is emulated. Valid values are specific to the
underlying hypervisor.
</p>
<p>
QEMU and KVM support:
</p>
<ul><li> 'i6300esb' — the recommended device,
emulating a PCI Intel 6300ESB </li><li> 'ib700' — emulating an ISA iBase IB700 </li></ul></dd><dt><code>action</code></dt><dd>
<p>
The optional <code>action</code> attribute describes what
action to take when the watchdog expires. Valid values are
specific to the underlying hypervisor.
</p>
<p>
QEMU and KVM support:
</p>
<ul><li>'reset' — default, forcefully reset the guest</li><li>'shutdown' — gracefully shutdown the guest
(not recommended) </li><li>'poweroff' — forcefully power off the guest</li><li>'pause' — pause the guest</li><li>'none' — do nothing</li><li>'dump' — automatically dump the guest
<span class="since">Since 0.8.7</span></li></ul><p>
Note 1: the 'shutdown' action requires that the guest
is responsive to ACPI signals. In the sort of situations
where the watchdog has expired, guests are usually unable
to respond to ACPI signals. Therefore using 'shutdown'
is not recommended.
</p>
<p>
Note 2: the directory to save dump files can be configured
by <code>auto_dump_path</code> in file /etc/libvirt/qemu.conf.
</p>
</dd></dl>
<h4>
<a name="elementsMemBalloon" id="elementsMemBalloon">Memory balloon device</a>
</h4>
<p>
A virtual memory balloon device is added to all Xen and KVM/QEMU
guests. It will be seen as <code>memballoon</code> element.
It will be automatically added when appropriate, so there is no
need to explicitly add this element in the guest XML unless a
specific PCI slot needs to be assigned.
<span class="since">Since 0.8.3, Xen, QEMU and KVM only</span>
Additionally, <span class="since">since 0.8.4</span>, if the
memballoon device needs to be explicitly disabled,
<code>model='none'</code> may be used.
</p>
<p>
Example automatically added device with KVM
</p>
<pre>
...
<devices>
<memballoon model='virtio'/>
</devices>
...</pre>
<p>
Example manually added device with static PCI slot 2 requested
</p>
<pre>
...
<devices>
<watchdog model='virtio'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/>
</devices>
</domain></pre>
<dl><dt><code>model</code></dt><dd>
<p>
The required <code>model</code> attribute specifies what type
of balloon device is provided. Valid values are specific to
the virtualization platform
</p>
<ul><li>'virtio' — default with QEMU/KVM</li><li>'xen' — default with Xen</li></ul></dd></dl>
<h3>
<a name="seclabel" id="seclabel">Security label</a>
</h3>
<p>
The <code>seclabel</code> element allows control over the
operation of the security drivers. There are two basic
modes of operation, dynamic where libvirt automatically
generates a unique security label, or static where the
application/administrator chooses the labels. With dynamic
label generation, libvirt will always automatically
relabel any resources associated with the virtual machine.
With static label assignment, by default, the administrator
or application must ensure labels are set correctly on any
resources, however, automatic relabeling can be enabled
if desired
</p>
<p>
Valid input XML configurations for the security label
are:
</p>
<pre>
<seclabel type='dynamic' model='selinux'/>
<seclabel type='dynamic' model='selinux'>
<baselabel>system_u:system_r:my_svirt_t:s0</baselabel>
</seclabel>
<seclabel type='static' model='selinux' relabel='no'>
<label>system_u:system_r:svirt_t:s0:c392,c662</label>
</seclabel>
<seclabel type='static' model='selinux' relabel='yes'>
<label>system_u:system_r:svirt_t:s0:c392,c662</label>
</seclabel>
</pre>
<p>
When viewing the XML for a running guest with automatic
resource relabeling active, an additional XML element,
<code>imagelabel</code>, will be included. This is an
output-only element, so will be ignored in user supplied
XML documents
</p>
<dl><dt><code>type</code></dt><dd>Either <code>static</code> or <code>dynamic</code> to determine
whether libvirt automatically generates a unique security label
or not.
</dd><dt><code>model</code></dt><dd>A valid security model name, matching the currently
activated security model
</dd><dt><code>relabel</code></dt><dd>Either <code>yes</code> or <code>no</code>. This must always
be <code>yes</code> if dynamic label assignment is used. With
static label assignment it will default to <code>no</code>.
</dd><dt><code>label</code></dt><dd>If static labelling is used, this must specify the full
security label to assign to the virtual domain. The format
of the content depends on the security driver in use
</dd><dt><code>baselabel</code></dt><dd>If dynamic labelling is used, this can optionally be
used to specify the base security label. The format
of the content depends on the security driver in use
</dd><dt><code>imagelabel</code></dt><dd>This is an output only element, which shows the
security label used on resources associated with the virtual domain.
The format of the content depends on the security driver in use
</dd></dl>
<h2>
<a name="examples" id="examples">Example configs</a>
</h2>
<p>
Example configurations for each driver are provide on the
driver specific pages listed below
</p>
<ul><li><a href="drvxen.html#xmlconfig">Xen examples</a></li><li><a href="drvqemu.html#xmlconfig">QEMU/KVM examples</a></li></ul>
</div>
</div>
<div id="footer">
<p id="sponsor">
Sponsored by:<br /><a href="http://et.redhat.com/"><img src="et.png" alt="Project sponsored by Red Hat Emerging Technology" /></a></p>
</div>
</body>
</html>
|