This file is indexed.

/usr/share/octave/packages/control-3.0.0/Madievski.m is in octave-control 3.0.0-5.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
%% -*- texinfo -*-
%% Demonstration of frequency-weighted controller reduction.
%% The system considered in this example has been studied by Madievski and
%% Anderson [1] and comprises four spinning disks.  The disks are connected by a
%% flexible rod, a motor applies torque to the third disk, and the angular
%% displacement of the first disk is the variable of interest. The state-space
%% model of eighth order is non-minimumphase and unstable.
%% The continuous-time LQG controller used in [1] is open-loop stable and of
%% eighth order like the plant.  This eighth-order controller shall be reduced by
%% frequency-weighted singular perturbation approximation (SPA).
%% The major aim of this reduction is the preservation of the closed-loop
%% transfer function.  This means that the error in approximation of the
%% controller @var{K} by the reduced-order controller @var{Kr} is minimized by
%% @iftex
%% @tex
%% $$ \\underset{K_r}{\\min} \\ || W \\ (K - K_r) \\ V ||_{\\infty} $$
%% @end tex
%% @end iftex
%% @ifnottex
%% @example
%% min ||W (K-Kr) V||
%%  Kr               inf
%% @end example
%% @end ifnottex
%% where weights @var{W} and @var{V} are dictated by the requirement to preserve
%% (as far as possible) the closed-loop transfer function.  In minimizing the
%% error, they cause the approximation process for @var{K} to be more accurate at
%% certain frequencies.  Suggested by [1] is the use of the following stability
%% and performance enforcing weights:
%% @iftex
%% @tex
%% $$ W = (I - G K)^{-1} G,  \\qquad V = (I - G K)^{-1} $$
%% @end tex
%% @end iftex
%% @ifnottex
%% @example
%%              -1                      -1
%% W = (I - G K)   G,      V = (I - G K)
%% @end example
%% @end ifnottex
%% This example script reduces the eighth-order controller to orders four and two
%% by the function call
%% @code{Kr = spaconred (G, K, nr, 'feedback', '-')}
%% where argument @var{nr} denotes the desired order (4 or 2).  The key-value
%% pair @code{'feedback', '-'} allows the reduction of negative feedback
%% controllers while the default setting expects positive feedback controllers.
%% The frequency responses of the original and reduced-order controllers are
%% depicted in figure 1, the step responses of the closed loop in figure 2.
%% There is no visible difference between the step responses of the closed-loop
%% systems with original (blue) and fourth order (green) controllers.
%% The second order controller (red) causes ripples in the step response, but
%% otherwise the behavior of the system is unaltered.  This leads to the
%% conclusion that function @command{spaconred} is well suited to reduce the
%% order of controllers considerably, while stability and performance are
%% retained.
%% @*@strong{Reference}@*
%% [1] Madievski, A.G. and Anderson, B.D.O.
%% @cite{Sampled-Data Controller Reduction Procedure},
%% IEEE Transactions of Automatic Control,
%% Vol. 40, No. 11, November 1995

% ===============================================================================
% Frequency Weighted Controller Reduction       Lukas Reichlin      December 2011
% ===============================================================================

% Tabula Rasa
clear all, close all, clc

% Plant
Ap1 = [  0.0         1.0
         0.0         0.0     ];

Ap2 = [ -0.015       0.765
        -0.765      -0.015   ];

Ap3 = [ -0.028       1.410
        -1.410      -0.028   ];

Ap4 = [ -0.04        1.85
        -1.85       -0.04    ];

Ap = blkdiag (Ap1, Ap2, Ap3, Ap4);

Bp = [   0.026
        -0.251
         0.033
        -0.886
        -4.017
         0.145
         3.604
         0.280   ];

Cp = [  -0.996      -0.105       0.261       0.009      -0.001      -0.043       0.002      -0.026   ];

Dp = [   0.0     ];

P = ss (Ap, Bp, Cp, Dp);

% Controller
Ac = [  -0.4077      0.9741      0.1073      0.0131      0.0023     -0.0186     -0.0003     -0.0098
        -0.0977     -0.1750      0.0215     -0.0896     -0.0260      0.0057      0.0109     -0.0105
         0.0011      0.0218     -0.0148      0.7769      0.0034     -0.0013     -0.0014      0.0011
        -0.0361     -0.5853     -0.7701     -0.3341     -0.0915      0.0334      0.0378     -0.0290
        -0.1716     -2.6546     -0.0210     -1.4467     -0.4428      1.5611      0.1715     -0.1318
        -0.0020      0.0950      0.0029      0.0523     -1.3950     -0.0338     -0.0062      0.0045
         0.1607      2.3824      0.0170      1.2979      0.3721     -0.1353     -0.1938      1.9685
        -0.0006      0.1837      0.0048      0.1010      0.0289     -0.0111     -1.8619     -0.0311  ];

Bc = [  -0.4105
        -0.0868
        -0.0004
         0.0036
         0.0081
        -0.0085
        -0.0004
        -0.0132  ];

Cc = [  -0.0447     -0.6611     -0.0047     -0.3601     -0.1033      0.0375      0.0427     -0.0329  ];

Dc = [   0.0     ];

K = ss (Ac, Bc, Cc, Dc);

% Controller Reduction
Kr4 = spaconred (P, K, 4, 'feedback', '-')
Kr2 = spaconred (P, K, 2, 'feedback', '-')

% Open Loop
L = P * K;
Lr4 = P * Kr4;
Lr2 = P * Kr2;

% Closed Loop
T = feedback (L);
Tr4 = feedback (Lr4);
Tr2 = feedback (Lr2);

% Frequency Range
w = {1e-2, 1e1};

% Bode Plot of Controller
figure (1)
bode (K, Kr4, Kr2, w)
legend ('K (8 states)', 'Kr (4 states)', 'Kr (2 states)', 'Location', 'SouthWest')
    
% Step Response of Closed Loop
figure (2)
step (T, Tr4, Tr2, 100)
legend ('K (8 states)', 'Kr (4 states)', 'Kr (2 states)', 'Location', 'SouthEast')