1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 | # $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Configuration for a Rockwell-based modem not otherwise handled by
# another prototype configuration file. This file assumes the modem
# is compatible with the Rc144AC, RC96AC or RC144DP.
#
# This configuration file sets up the modem to run at 38.4 with
# RTS/CTS flow control used by default. XON/XOFF is automatically
# enabled for fax recv. Beware of modems that also lock sending
# to 19.2; add ModemSendBeginCmd: "<19200>" if this is required.
# Also beware that the adaptive-answer facility, when supported,
# is often unreliable.
#
# CONFIG: CLASS2: ROCKWELL*-*
#
# BEGIN-SERVER
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 19200
ModemFlowControl: rtscts # default
#
#ModemResetCmds: AT&F2 # what you want for a Supra
ModemNoFlowCmd: AT&K # disable flow control cmd
ModemHardFlowCmd: AT&K3 # hardware flow control cmd
ModemSoftFlowCmd: AT&K4 # software flow control cmd
ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
#ModemSetupDTRCmd: AT&D2S25=1S38=0 # Dynalink 1414VE needs this
ModemSetupDCDCmd: AT&C1 # DCD follows carrier
ModemSetupAACmd: AT+FAA=1+FCLASS=0 # enable in current class
#
ModemSendFillOrder: LSB2MSB # as expected
ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
#
ModemAnswerFaxBeginCmd: "<19200><xon>" # modem switches on fax receive
#
# Caller ID configuration setup for Supra.
#
#QualifyCID: etc/cid # CID access control list file
#CallIDPattern: "NMBR = " # pattern string for phone number info
#CallIDPattern: "NAME = " # pattern string for identity info
|