# $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Configuration for a Rockwell RC288DPi-based Class 2 modem
# (should also work for 144DPi-based modems).
#    Microcom DeskPorte 28.8S	firmware rev V1.100K-V34_DS
#    (and others)
#
# NB: DCD is toggled at page end during transmits; this can
#     cause problems on systems where it's not possible to
#     set CLOCAL and also enable RTS/CTS flow control.
#
# CONFIG: CLASS2: ROCKWELL-AC/V34-*
# CONFIG: CLASS2: "Supra Corporation"-"Supra 288i Sp"-*
# CONFIG: CLASS2: "BEST DATA PRODUCTS"-"2834VF"-*
# CONFIG: CLASS2: Boca*-33,600*-*
#
# BEGIN-SERVER
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class2		# use class 1 interface
ModemRate:		19200		# locked for fax sending&receiving
ModemFlowControl:	rtscts		# default
#
ModemNoFlowCmd:		AT&K0		# disable flow control cmd
ModemSoftFlowCmd:	AT&K4		# software flow control cmd
ModemHardFlowCmd:	AT&K3		# hardware flow control cmd
ModemSetupDTRCmd:	AT&D3		# DTR off causes modem to reset
ModemSetupDCDCmd:	AT&C1		# DCD follows carrier
ModemSetupAACmd:	AT+FAA=1	# enable adaptive-answer in Class 2
#
ModemRecvFillOrder:	MSB2LSB		# bit order of received facsimile
ModemSendFillOrder:	LSB2MSB		# bit order modem expects for transmit
#
ModemDialCmd:		ATDT%s		# T for tone dialing
#
# Chip locks the line rate and switches to xon/xoff flow
# control when receiving facsimile--we must follow suit.
#
ModemAnswerFaxBeginCmd:	"<19200><xon>"	# lock line rate & switch flow control
#
Class2RecvDataTrigger:	"\022"		# character sent to modem to start recv
Class2BUGCmd:		none		# AC/V34 gives ERROR
Class2APQueryCmd:	none		# AC/V34 gives ERROR