1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 | #!/bin/sh
# External STONITH module that uses the NUT daemon to control an external UPS.
# See the comments below, and the various NUT man pages, for how this
# script works. It should work unchanged with most modern "smart" APC UPSes in
# a Redhat/Fedora/RHEL-style distribution with the nut package installed.
# Author: William Seligman <seligman@nevis.columbia.edu>
# License: GPLv2
# As you're designing your UPS and STONITH set-up, it may help to consider that
# there can be potentially three computers involved:
# 1) the machine running this STONITH module;
# 2) the machine being controlled by this STONITH module ($hostname);
# 3) the machine that can send commands to the UPS.
# On my cluster, all the UPSes have SNMP smartcards, so every host can communicate
# with every UPS; in other words, machines (1) and (3) are the same. If your UPSes
# are controlled via serial or USB connections, then you might have a
# situation in which $hostname is plugged into a UPS, which has a serial connection
# to some master "power-control" computer, and can potentially be STONITHed
# by any other machine in your cluster.
# In general, you'll probably need the nut daemon running on both the hosts (1) and
# (3) in the above list. The NUT daemon will also have to run on (2) if you want the
# reset command to gracefully reboot $hostname.
# The NUT command default locations. In the RHEL-type nut packages, these binaries
# are in /usr/bin.
RHELUPSCMD="/usr/bin/upscmd"
RHELUPSC="/usr/bin/upsc"
# Defaults for APC smart UPSes:
# Reset = reboot $hostname; this will be a graceful reboot if the host
# is running NUT and monitoring $ups.
APCRESET="shutdown.return"
# Poweroff = turn off $hostname immediately by cutting the power on $ups.
# For a graceful shutdown, use shutdown.stayoff instead of load.off,
# but it might take a few minutes to shutdown in this way.
APCPOWEROFF="load.off"
# Poweron = turn on the power to $ups, which will presumably turn on $hostname.
# (Did you set $hostname's BIOS to boot up on AC power restore, as opposed to
# "last state"?)
APCPOWERON="load.on"
# Status = returns a short string with the $ups status; OL = on-line, OFF = off-line, etc.
APCSTATUSVAR="ups.status"
# Stick in the defaults, if needed.
if [ -z "${poweron}" ]; then
poweron=${APCPOWERON}
fi
if [ -z "${poweroff}" ]; then
poweroff=${APCPOWEROFF}
fi
if [ -z "${reset}" ]; then
reset=${APCRESET}
fi
if [ -z "${statusvar}" ]; then
statusvar=${APCSTATUSVAR}
fi
if [ -z "${upscmd}" ]; then
upscmd=${RHELUPSCMD}
fi
if [ -z "${upsc}" ]; then
upsc=${RHELUPSC}
fi
# Define the command to fetch the UPS status.
STATUSCMD="${upsc} ${ups} ${statusvar}"
usage() {
echo "Usage: $0 {on|off|reset|status|gethosts|getconfignames|getinfo-devid|getinfo-devname|getinfo-devdescr|getinfo-devurl|getinfo-xml}"
}
# Can we find the NUT binary?
have_nut() {
test -x "${upscmd}"
}
have_upsc() {
test -x "${upsc}"
}
do_nut() {
have_nut || {
echo "Can't find NUT upscmd command"
return 1
}
if [ -z "${username}" -o -z "${password}" -o -z "${ups}" ]; then
echo "username, password or ups name missing; check configuration"
return 1
fi
# Execute the command given in argument 1.
${upscmd} -u ${username} -p ${password} ${ups} ${1} || {
echo "error executing nut command"
return 1
}
}
case ${1} in
gethosts)
echo ${hostname}
exit 0
;;
on)
result=1
do_nut "${poweron}"
result=$?
exit ${result}
;;
off)
result=1
do_nut "${poweroff}"
result=$?
exit ${result}
;;
reset)
result=1
do_nut "${reset}"
result=$?
exit $result
;;
status)
have_upsc || {
echo "Can't find NUT upsc command"
exit 1
}
${STATUSCMD}
exit $?
;;
getconfignames)
echo "hostname ups username password poweron poweroff reset statusvar upscmd upsc"
exit 0
;;
getinfo-devid)
echo "NUT STONITH device"
exit 0
;;
getinfo-devname)
echo "NUT STONITH external device"
exit 0
;;
getinfo-devdescr)
echo "A STONITH device based on NUT (Network UPS Tools)."
echo " "
echo "For this STONITH script to work, the following conditions have"
echo "to be met:"
echo " "
echo "- NUT has to be installed on both the host running this script"
echo " and the host that controls the UPS (on RHEL systems, NUT is"
echo " in packages nut and nut-client) and the nut daemon services"
echo " (normally called the ups or upsd service) must be running"
echo " on both systems."
echo " "
echo "- The UPS name has to be defined in ups.conf on the host"
echo " that controls the UPS."
echo " "
echo "- The username/password to access the UPS must be defined in"
echo " upsd.users on the host that controls the UPS, with the instcmds"
echo " for poweron, poweroff, and reset allowed."
echo " "
echo "- The host that is running this script must be allowed access"
echo " via upsd.conf and upsd.users on the host the controls the UPS."
echo " "
echo "On RHEL systems, the files listed above are in /etc/ups."
echo " "
echo "The defaults will probably work with APC UPS devices. It might"
echo "work on others; 'upscmd -l (ups)' and 'upsc (ups)' will list"
echo "the commands and variables, and you can change the values"
echo "for poweron, poweroff, reset, and statusvar to suit your UPS."
echo "Change upscmd and upsc if your NUT binaries are not in /usr/bin."
exit 0
;;
getinfo-devurl)
echo "http://www.networkupstools.org/"
exit 0
;;
getinfo-xml)
cat << nutXML
<parameters>
<parameter name="hostname" unique="1" required="1">
<content type="string" default="" />
<shortdesc lang="en">Hostname</shortdesc>
<longdesc lang="en">
The name of the host to be managed by this STONITH device.
The nut daemon must be running on the host controllng the
UPS _and_ on the host running this script; this script does
not start/stop the daemons for you.
</longdesc>
</parameter>
<parameter name="ups" required="1">
<content type="string" default="" />
<shortdesc lang="en">UPS name</shortdesc>
<longdesc lang="en">
The name of the UPS as defined in ups.conf on the host
controlling the UPS. The format for this option is
upsname[@controlhost[:port]]. The default controlhost is
"localhost".
</longdesc>
</parameter>
<parameter name="username" required="1">
<content type="string" default="" />
<shortdesc lang="en">Username</shortdesc>
<longdesc lang="en">
The username used for accessing the UPS. This is defined in
upsd.conf on the host controlling the UPS.
</longdesc>
</parameter>
<parameter name="password" required="1">
<content type="string" default="" />
<shortdesc lang="en">Password</shortdesc>
<longdesc lang="en">
The password used for logging in to the UPS for the host
controlling the UPS, as defined in upsd.conf on that host.
</longdesc>
</parameter>
<parameter name="poweron">
<content type="string" default="$APCPOWERON" />
<shortdesc lang="en">UPS Power On command</shortdesc>
<longdesc lang="en">
The NUT hardware command to turn on the UPS. The default
should work for most "smart" APC UPSes. For a list of
commands that your UPS can support, type 'upscmd -l (ups)'
on the command line.</longdesc>
</parameter>
<parameter name="poweroff">
<content type="string" default="$APCPOWEROFF" />
<shortdesc lang="en">UPS Power Off command</shortdesc>
<longdesc lang="en">
The NUT hardware command to turn off the UPS. On most APC
"smart" UPSes, the command shutdown.stayoff will result
in a graceful shutdown, provided the host is running the
nut daemon, but this might take a few minutes; load.off
will cut the power immediately. For a list of commands that
your UPS can support, type 'upscmd -l (ups)' on the command
line.
</longdesc>
</parameter>
<parameter name="reset">
<content type="string" default="$APCRESET" />
<shortdesc lang="en">UPS Reset command</shortdesc>
<longdesc lang="en">
The NUT hardware command to reset the host. On most APC
"smart" UPSes, the command shutdown.return will result
in a graceful shutdown, with power restored after perhaps
a short interval. For a list of commands that your UPS can
support, type 'upscmd -l (ups)' on the command line.
</longdesc>
</parameter>
<parameter name="statusvar">
<content type="string" default="$APCSTATUSVAR" />
<shortdesc lang="en">UPS Status variable</shortdesc>
<longdesc lang="en">
The NUT variable that returns the status of the UPS. On APC
UPSes, the value of ups.status will be "OL" if the UPS is
"on-line." For a list of variables that your UPS supports,
type 'upsc (ups)' on the command line.
</longdesc>
</parameter>
<parameter name="upscmd">
<content type="string" default="$RHELUPSCMD" />
<shortdesc lang="en">upscmd binary location</shortdesc>
<longdesc lang="en">
The full path to the NUT binary command 'upscmd'. On RHEL
systems with the nut RPM installed, this location is
/usr/bin/upscmd.
</longdesc>
</parameter>
<parameter name="upsc">
<content type="string" default="$RHELUPSC" />
<shortdesc lang="en">upsc binary location</shortdesc>
<longdesc lang="en">
The full path to the NUT binary command 'upsc'. On RHEL
systems with the nut RPM installed, this location is
/usr/bin/upsc.
</longdesc>
</parameter>
</parameters>
nutXML
exit 0
;;
*)
usage
exit 1
;;
esac
|