/var/spool/hylafax/config/rc288dpi-1 is in hylafax-server 3:6.0.6-5.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 | # $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Configuration for a Rockwell RC288DPi-based Class 1 modem.
# Hayes Optima 28800 firmware rev ???
# Microcom DeskPorte 28.8S firmware rev V1.100K-V34_DS
# PPI PM288FXMT firmware rev 1.57
#
# Note that the modem does not lock the line rate for fax
# receive (at least not the PM288FXMT); but not sure whether
# current flow control settings are maintained or if it
# switches to XON/XOFF (testing host was too fast to see).
#
# CONFIG:CLASS1:28800:.*:.*: Manufacturer=ROCKWELL Model=RC288DPi
# CONFIG:CLASS1:33600:.*:.*: Manufacturer=Rockwell Model=33600
# CONFIG:CLASS1:56000:.*:.*: Manufacturer=Rockwell/Conexant Model=AC/K56
# CONFIG:CLASS1:MT5600ZDX:.*:.*: Manufacturer=MultiTech Model=MT5600ZDX
#
# BEGIN-SERVER
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class1 # use this to supply a hint
ModemRate: 19200 # rate for DCE-DTE communication
ModemFlowControl: rtscts # default
#
ModemNoFlowCmd: AT&K0 # setup no flow control
ModemHardFlowCmd: AT&K3 # setup hardware flow control
ModemSoftFlowCmd: AT&K4 # setup software flow control
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
#
ModemMfrQueryCmd: !Rockwell
ModemModelQueryCmd: !RC288DPi
ModemRevQueryCmd: ATI3 # product information
#
ModemDialCmd: ATDT%s # T for tone dialing
|