This file is indexed.

/var/spool/hylafax/config/rc288dpi-1 is in hylafax-server 3:6.0.6-5.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
# $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Configuration for a Rockwell RC288DPi-based Class 1 modem.
#    Hayes Optima 28800		firmware rev ???
#    Microcom DeskPorte 28.8S	firmware rev V1.100K-V34_DS
#    PPI PM288FXMT		firmware rev 1.57
#
# Note that the modem does not lock the line rate for fax
# receive (at least not the PM288FXMT); but not sure whether
# current flow control settings are maintained or if it
# switches to XON/XOFF (testing host was too fast to see).
#
# CONFIG:CLASS1:28800:.*:.*: Manufacturer=ROCKWELL Model=RC288DPi
# CONFIG:CLASS1:33600:.*:.*: Manufacturer=Rockwell Model=33600
# CONFIG:CLASS1:56000:.*:.*: Manufacturer=Rockwell/Conexant Model=AC/K56
# CONFIG:CLASS1:MT5600ZDX:.*:.*: Manufacturer=MultiTech Model=MT5600ZDX
#
# BEGIN-SERVER
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class1		# use this to supply a hint
ModemRate:		19200		# rate for DCE-DTE communication
ModemFlowControl:	rtscts		# default
#
ModemNoFlowCmd:		AT&K0		# setup no flow control
ModemHardFlowCmd:	AT&K3		# setup hardware flow control
ModemSoftFlowCmd:	AT&K4		# setup software flow control
ModemSetupDTRCmd:	AT&D2		# setup so DTR drop resets modem
ModemSetupDCDCmd:	AT&C1		# setup so DCD reflects carrier (or not)
#
ModemMfrQueryCmd:	!Rockwell
ModemModelQueryCmd:	!RC288DPi
ModemRevQueryCmd:	ATI3		# product information
#
ModemDialCmd:		ATDT%s		# T for tone dialing