/usr/share/pyshared/zope/testrunner/testrunner-layers-buff.txt is in python-zope.testrunner 4.0.3-3.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 | This is a test for a fix in buffering of output from a layer in a subprocess.
Prior to the change that this tests, output from within a test layer in a
subprocess would be buffered. This could wreak havoc on supervising processes
(or human) that would kill a test run if no output was seen for some period of
time.
First, we wrap stdout with an object that instruments it. It notes the time at
which a given line was written.
>>> import os, sys, datetime
>>> class RecordingStreamWrapper:
... def __init__(self, wrapped):
... self.record = []
... self.wrapped = wrapped
... def write(self, out):
... self.record.append((out, datetime.datetime.now()))
... self.wrapped.write(out)
... def flush(self):
... self.wrapped.flush()
...
>>> sys.stdout = RecordingStreamWrapper(sys.stdout)
Now we actually call our test. If you open the file to which we are referring
here (zope/testing/testrunner-ex/sampletests_buffering.py) you will see two test
suites, each with its own layer that does not know how to tear down. This
forces the second suite to be run in a subprocess.
That second suite has two tests. Both sleep for half a second each.
>>> directory_with_tests = os.path.join(this_directory, 'testrunner-ex')
>>> from zope import testrunner
>>> defaults = [
... '--path', directory_with_tests,
... ]
>>> argv = [sys.argv[0],
... '-vv', '--tests-pattern', '^sampletests_buffering.*']
>>> try:
... testrunner.run_internal(defaults, argv)
... record = sys.stdout.record
... finally:
... sys.stdout = sys.stdout.wrapped
...
Running tests at level 1
Running sampletests_buffering.Layer1 tests:
Set up sampletests_buffering.Layer1 in N.NNN seconds.
Running:
test_something (sampletests_buffering.TestSomething1)
Ran 1 tests with 0 failures and 0 errors in N.NNN seconds.
Running sampletests_buffering.Layer2 tests:
Tear down sampletests_buffering.Layer1 ... not supported
Running in a subprocess.
Set up sampletests_buffering.Layer2 in N.NNN seconds.
Running:
test_something (sampletests_buffering.TestSomething2)
test_something2 (sampletests_buffering.TestSomething2)
Ran 2 tests with 0 failures and 0 errors in N.NNN seconds.
Tear down sampletests_buffering.Layer2 ... not supported
Total: 3 tests, 0 failures, 0 errors in N.NNN seconds.
False
Now we actually check the results we care about. We should see that there are
two pauses of about half a second, one around the first test and one around the
second. Before the change that this test verifies, there was a single pause of
more than a second after the second suite ran.
>>> pause = datetime.timedelta(seconds=0.3)
>>> last_line, last_time = record.pop(0)
>>> for line, time in record:
... if time-last_time >= pause:
... # We paused!
... print 'PAUSE FOUND BETWEEN THESE LINES:'
... print ''.join([last_line, line, '-'*70])
... last_line, last_time = line, time
... # doctest: +ELLIPSIS
PAUSE FOUND BETWEEN THESE LINES:...
Running:
test_something (sampletests_buffering.TestSomething2)
----------------------------------------------------------------------
PAUSE FOUND BETWEEN THESE LINES:
test_something (sampletests_buffering.TestSomething2)
test_something2 (sampletests_buffering.TestSomething2)
----------------------------------------------------------------------
Because this is a test based on timing, it may be somewhat fragile. However,
on a relatively slow machine, this timing works out fine; I'm hopeful that this
test will not be a source of spurious errors. If it is, we will have to
readdress.
Now let's do the same thing, but with multiple processes at once. We'll get
a different result that has similar characteristics.
>>> sys.stdout = RecordingStreamWrapper(sys.stdout)
>>> argv.extend(['-j', '2'])
>>> try:
... testrunner.run_internal(defaults, argv)
... record = sys.stdout.record
... finally:
... sys.stdout = sys.stdout.wrapped
...
Running tests at level 1
Running sampletests_buffering.Layer1 tests:
Set up sampletests_buffering.Layer1 in N.NNN seconds.
Running:
test_something (sampletests_buffering.TestSomething1)
Ran 1 tests with 0 failures and 0 errors in N.NNN seconds.
[Parallel tests running in sampletests_buffering.Layer2:
.. LAYER FINISHED]
Running sampletests_buffering.Layer2 tests:
Running in a subprocess.
Set up sampletests_buffering.Layer2 in N.NNN seconds.
Ran 2 tests with 0 failures and 0 errors in N.NNN seconds.
Tear down sampletests_buffering.Layer2 ... not supported
Tearing down left over layers:
Tear down sampletests_buffering.Layer1 ... not supported
Total: 3 tests, 0 failures, 0 errors in N.NNN seconds.
False
Notice that, with a -vv (or greater) verbosity, the parallel test run includes
a progress report to keep track of tests run in the various layers. Because
the actual results are saved to be displayed assembled in the original test
order, the progress report shows up before we are given the news that the
testrunner is starting Layer2. This is counterintuitive, but lets us keep the
primary reporting information for the given layer in one location, while also
giving us progress reports that can be used for keepalive analysis by a human or
automated agent. In particular for the second point, notice below that, as
before, the progress output is not buffered.
>>> last_line, last_time = record.pop(0)
>>> for line, time in record:
... if time-last_time >= pause:
... # We paused!
... print 'PAUSE FOUND BETWEEN THIS OUTPUT:'
... print '\n'.join([last_line, line, '-'*70])
... last_line, last_time = line, time
... # doctest: +ELLIPSIS
PAUSE FOUND BETWEEN THIS OUTPUT:...
.
.
----------------------------------------------------------------------
PAUSE FOUND BETWEEN THIS OUTPUT:
.
LAYER FINISHED
----------------------------------------------------------------------
Fake an IOError reading the output of the subprocess to exercise the
reporting of that error:
>>> class FakeStdout(object):
... raised = False
... def __init__(self, msg):
... self.msg = msg
... def readline(self):
... if not self.raised:
... self.raised = True
... raise IOError(self.msg)
>>> class FakeStderr(object):
... def __init__(self, msg):
... self.msg = msg
... def read(self):
... return self.msg
>>> class FakeProcess(object):
... def __init__(self, out, err):
... self.stdout = FakeStdout(out)
... self.stderr = FakeStderr(err)
>>> class FakePopen(object):
... def __init__(self, out, err):
... self.out = out
... self.err = err
... def __call__(self, *args, **kw):
... return FakeProcess(self.out, self.err)
>>> import subprocess
>>> Popen = subprocess.Popen
>>> subprocess.Popen = FakePopen(
... "Failure triggered to verify error reporting",
... "0 0 0")
>>> directory_with_tests = os.path.join(this_directory, 'testrunner-ex')
>>> from zope import testrunner
>>> defaults = [
... '--path', directory_with_tests,
... ]
>>> argv = [sys.argv[0],
... '-vv', '--tests-pattern', '^sampletests_buffering.*']
>>> _ = testrunner.run_internal(defaults, argv)
Running tests at level 1
Running sampletests_buffering.Layer1 tests:
Set up sampletests_buffering.Layer1 in N.NNN seconds.
Running:
test_something (sampletests_buffering.TestSomething1)
Ran 1 tests with 0 failures and 0 errors in N.NNN seconds.
Running sampletests_buffering.Layer2 tests:
Tear down sampletests_buffering.Layer1 ... not supported
Error reading subprocess output for sampletests_buffering.Layer2
Failure triggered to verify error reporting
Total: 1 tests, 0 failures, 0 errors in N.NNN seconds.
Now fake an empty stderr to test reporting a failure when
communicating with the subprocess:
>>> subprocess.Popen = FakePopen(
... "Failure triggered to verify error reporting",
... "")
>>> directory_with_tests = os.path.join(this_directory, 'testrunner-ex')
>>> from zope import testrunner
>>> defaults = [
... '--path', directory_with_tests,
... ]
>>> argv = [sys.argv[0],
... '-vv', '--tests-pattern', '^sampletests_buffering.*']
>>> _ = testrunner.run_internal(defaults, argv)
Running tests at level 1
Running sampletests_buffering.Layer1 tests:
Set up sampletests_buffering.Layer1 in N.NNN seconds.
Running:
test_something (sampletests_buffering.TestSomething1)
Ran 1 tests with 0 failures and 0 errors in N.NNN seconds.
Running sampletests_buffering.Layer2 tests:
Tear down sampletests_buffering.Layer1 ... not supported
Error reading subprocess output for sampletests_buffering.Layer2
Failure triggered to verify error reporting
<BLANKLINE>
**********************************************************************
Could not communicate with subprocess
**********************************************************************
<BLANKLINE>
Total: 1 tests, 0 failures, 0 errors in N.NNN seconds.
>>> subprocess.Popen = Popen
|