1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 | % RefitCalGamma
%
% Refit the gamma data from a calibration.
%
% 3/27/02 dhb Wrote it.
% 8/26/03 dhb, jl Allow changing dacsize of calibraiton. Useful for dropping from 10 to 8.
% 2/2/05 dhb, dam Ask for filename to save to, rather than automatically overwrite.
% 9/26/08 dhb, ijk, tyl Simplify naming possibilities. Add some better help.
% 9/27/08 dhb Fix up dacsize fitting.
% Clearer prompts (show default values).
% 11/19/09 dhb Added crtSumPow option. This works great for our FrontRoom monitor, which
% was not well fit by the traditional gamma model. The work is done in
% function CalibrateFitGamma. See comments there.
% 11/20/09 dhb More terms in crtSumPow.
% 3/07/10 dhb Call CalibrateFitLinMod as well.
% 3/08/10 dhb Update list of fit type options.
% 5/28/10 dhb Add yoked fitting routine to calls. Should have no effect when yoked isn't set, but do the right thing when it is.
% 6/5/10 dhb Update type list provided to user.
% dhb Better plots, using plot subroutines.
% Enter load code
defaultFileName = 'monitor';
thePrompt = sprintf('Enter calibration filename [%s]: ',defaultFileName);
newFileName = input(thePrompt,'s');
if (isempty(newFileName))
newFileName = defaultFileName;
end
fprintf(1,'\nLoading from %s.mat\n',newFileName);
cal = LoadCalFile(newFileName);
fprintf('Calibration file %s read\n\n',newFileName);
% Print out some information from the calibration.
DescribeMonCal(cal);
% Provide information about gamma measurements
% This is probably not method-independent.
fprintf('Gamma measurements were made at %g levels\n',...
size(cal.rawdata.rawGammaInput,1));
fprintf('Gamma table available at %g levels\n',...
size(cal.gammaInput,1));
% Get new fit type
fprintf('Old gamma fit type was: %s\n',cal.describe.gamma.fitType);
oldType = cal.describe.gamma.fitType;
fprintf('Possible fit types are defined by routine CalibrateFitGamma\n');
fprintf('See "help CalibrateFitGamma for most up to date options\n');
fprintf('Current (June, 2010) options are:\n');
fprintf('\tsimplePower\n');
fprintf('\tcrtLinear\n');
fprintf('\tcrtPolyLinear\n');
fprintf('\tcrtGamma\n');
fprintf('\tcrtSumPow\n');
fprintf('\tbetacdf\n');
fprintf('\tsigmoid\n');
fprintf('\tweibull\n');
gamma.fitType= GetWithDefault('Enter new fit type',oldType);
cal.describe.gamma = gamma;
if (strcmp(gamma.fitType,'betacdf'))
cal.describe.gamma.useweight = GetWithDefault('Enter weighting constant (-1 -> no weighting)',0.01);
end
% Get new number of bits
fprintf('Old DAC bits was: %d\n',cal.describe.dacsize);
oldDacsize = cal.describe.dacsize;
cal.describe.dacsize = input(sprintf('Enter new dacsize: [%d]: ',oldDacsize));
if (isempty(cal.describe.dacsize))
cal.describe.dacsize = oldDacsize;
end
% Change dacsize? Used every once in a while.
if (cal.describe.dacsize ~= oldDacsize)
bits = cal.describe.dacsize;
end
% Now refit
cal = CalibrateFitLinMod(cal);
cal = CalibrateFitYoked(cal);
cal = CalibrateFitGamma(cal,2^cal.describe.dacsize);
% Put up a plot of the essential data
CalibratePlotSpectra(cal,figure(1));
CalibratePlotGamma(cal,figure(2));
drawnow;
% Option to save the refit file
saveIt = input('Save new fit data (0->no, 1->yes)? [0]: ');
if (isempty(saveIt))
saveIt = 0;
end
if (saveIt)
% Prompt for new file name if we're saving to a name.
defaultFileName = newFileName;
thePrompt = sprintf('Enter calibration filename [%s]: ',defaultFileName);
saveFileName = input(thePrompt,'s');
if (isempty(saveFileName))
saveFileName = defaultFileName;
end
fprintf(1,'\nSaving to %s.mat\n',saveFileName);
SaveCalFile(cal,saveFileName);